Helukabel Single 600-CY-J/-O Special Single Core Cable 600V EMC-Preferred Type Meter Marking Cable

Helukabel Single 600-CY-J/-O Special Single Core Cable 600V EMC-Preferred Type Meter Marking Cable

Select gauge from drop-down menu for prices:

Helukabel Single 600-CY-J/-O Special Single Core Cable 600V EMC-Preferred Type Meter Marking Cable

Technical Data:
• Special PVC single core acc. to UL Style 10107 and CSA AWM I/II A/B, adapted to DIN VDE 0285-525-2-31 / DIN EN 50525-2-31, DIN VDE 0285-525-2-51 / DIN EN 50525-2-51, acc. to UL Std.758

Temperature Range:
• flexing -5°C bis +90°C
• fixed installation -40°C bis +90°C

Permissible Conductor Operating Temperature: +90°C

Nominal Voltage:
• VDE U0/U 600/1000 V
• UL/CSA 600 V

Test Voltage:
• 4000 V

Breakdown Voltage:
• min. 8000 V 

Minimum Bending Radius:
• flexing 7,5x cable Ø
• fixed installation 4x cable Ø

Radiation Resistance:
• up to 80x106 cJ/kg (up to 80 Mrad)

Cable Structure:
• Bare copper, fine wire conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5
• Core insulation of special PVC to class 43, 90°C acc. to UL Std.1581 colour black or green-yellow
• Tinned copper braided screening, coverage approx. 85%
• Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1/ DIN EN 50363-4-1 and class 43 acc. to UL Std.1581
• Sheath colour: black (RAL 9005)
• With meter marking

Properties:
• Chemical Resistance see "Technical Informations"
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
• UV resistant

Tests:
• PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B), UL VW-1, CSA FT1

Note:
• G = green-yellow x = black
• AWG sizes are approximate equivalent values. The actual cross section is in mm².
• UnScreened analogue type: Single 600-J / -O
• Also as 1000 V Style 10678 deliverable

Application:
• PVC Single cores suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burrial- or as underwater cable. These two norms approved single cores designed for exportorientated machinery manufacturer for machine tools, conveyor belts and production lines. These screened cables are particulary suitable for the interference-free transmission in instrumentation and control engineering applications (electromagnetic compatibility).
• EMC = Electromagnetic compatibility
• To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
• = Product conforms with Low-Voltage Directive 2014/35/EU.

awg-no. no.cores x
cross-sec.mm²
weight app.
kg/km
helukabel
part number
action
10 1 G 6 140,0 10910 Request A Quote
10 1 X 6 140,0 10911 Request A Quote
8 1 G 10 230,0 10912 Request A Quote
8 1 X 10 230,0 10913 Request A Quote
6 1 G 16 300,0 10914 Request A Quote
6 1 X 16 300,0 10915 Request A Quote
4 1 G 25 420,0 10916 Request A Quote
4 1 X 25 420,0 10917 Request A Quote
2 1 G 35 615,0 10918 Request A Quote
2 1 X 35 615,0 10919 Request A Quote
1 1 G 50 825,0 10920 Request A Quote
1 1 X 50 825,0 10921 Request A Quote
2/0 1 G 70 1090,0 10922 Request A Quote
2/0 1 X 70 1090,0 10923 Request A Quote
3/0 1 G 95 1395,0 10924 Request A Quote
3/0 1 X 95 1395,0 10925 Request A Quote
4/0 1 G 120 1770,0 10926 Request A Quote
4/0 1 X 120 1770,0 10927 Request A Quote
250 MCM 1 G 150 1930,0 10928 Request A Quote
250 MCM 1 X 150 1930,0 10929 Request A Quote
350 MCM 1 G 185 2635,0 10930 Request A Quote
350 MCM 1 X 185 2635,0 10931 Request A Quote
450 MCM 1 G 240 3380,0 10932 Request A Quote
450 MCM 1 X 240 3380,0 10933 Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question