Belden 9306 Cable 22 AWG 6 Pairs Overall Beldfoil Shield Audio Control and Instrumentation Multi Conductor Solid PVC Jacket Cable

Belden 9306 Cable 22 AWG 6 Pairs Overall Beldfoil Shield Audio Control and Instrumentation Multi Conductor Solid PVC Jacket Cable

Min Length: 100 FT

Regular price $7.46 $5.54 Sale /per Foot

Belden 9306 Cable 22 AWG 6 Pairs Overall Beldfoil Shield Audio Control and Instrumentation Multi Conductor Solid PVC Jacket Cable

Description:
• 22 AWG solid tinned copper conductors, PVC insulation, twisted pairs, overall Beldfoil shield (100% coverage), 22 AWG stranded TC drain wire, PVC jacket.

Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.3302

Outer Shield Drain Wire AWG:
• AWG: 22
• Stranding: 7x30
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.8128

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 2464)
• Bulk Cable Weight: 84.827 Kg/Km
• Max. Recommended Pulling Tension: 453.716 N
• Min. Bend Radius/Minor Axis: 82.550 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Inductance (μH/m): 0.6562
• Nom. Capacitance Conductor to Shield (pF/m): 164.05
• Nom. Capacitance Conductor to Conductor (pF/m): 114.835
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 54.1365
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 41.0125
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 2.04 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 22
# pairs 6
stranding solid
no. of conductors 12
conductor material tinned copper
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable- nominal dia. (mm) 8.001
belden cable part number 9306

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question