*Data provided on this page is subject to change based on different manufacturers' variances
** Images are for display purposes only refer to Product Technical Details for accurate information on the product.
In the case the material only comes in a predetermined color or doesn’t come with any color
Product Details
instrumentation cables.No matter what gauge size, conductor count, insulation, jacket, armor or rating, Belden meets your need for reliability, performance, security and long life — guaranteed.
Benefits:
• Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit
• Superior electrical performance and longer runs in dozens of different environments
• Assured, flexible installation connections with all the necessary ratings
Features:
• Jacket options for excellent resistance to oil, outdoor sunlight/UV, flame and extreme temperatures
• Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexiblity
• Conductor options to provide increased flexibilty, greater flex life and corrosion resistance
Insulation:
• Material: PVC/Nylon - Polyvinyl Chloride/Nylon
Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.1938
• Outer Jacket Ripcord: Yes
Mechanical Charactertistics (Overall):
• Wet Temperature Range: -30°C To +75°C
• Dry Temperature Range: -30°C To +90°C
• Bulk Cable Weight: 45 lbs/1000 ft.
• Max. Recommended Pulling Tension: 81 lbs.
• Min. Bend Radius/Minor Axis: 2.900 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: NPLF, TC-ER
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: ICEA S-73-532, S-61-402
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 5.86
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 7.46
• Max. Operating Voltage - UL: 600 V RMS (NEC Type TC)
• Max. Operating Voltage - UL: 150 V RMS (NPLF)
• Max. Recommended Current: 6 Amps/conductor @ 25°C
Flame Test:
• UL Flame Test: UL1685 Vertical Tray Flame Test
• CSA Flame Test: FT4
• IEEE Flame Test: 1202
Suitability:
• Suitability - Burial: Yes
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
| awg | # triads | overall cable- nominal dia. (mm) |
belden cable part number |
Action |
| 18 | 1 | 7.366 | 1121A | Request A Quote |
| 18 | 1 | 7.366 | 3089A | Request A Quote |