Belden 1229A1 Cable 24 AWG 4 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable

Belden 1229A1 Cable 24 AWG 4 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 1229A1 Cable 24 AWG 4 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable

Regular price $0.34 Sale /per Foot

Belden 1229A1 Cable 24 AWG 4 Pairs Category 3 Nonbonded-Pair Multi Conductor U/UTP-UnShielded Solid Bare Copper PVC Jacket Cable

Description:
• CAT3, 4-Pair, U/UTP-Unshielded, Riser-CMR, Premise Horizontal Cable, 24 AWG Solid Bare Copper Conductors, Polyolefin Insulation, PVC Jacket.

Insulation:
• Material: PO - Polyolefin

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Diameter (in.): 0.197

Mechanical Characteristics (Overall):
• Operating Temperature Range: -20°C To +75°C
• Bulk Cable Weight: 29 lbs/1000 ft.
• Max. Recommended Pulling Tension: 35 lbs.
• Min. Bend Radius/Minor Axis: 1 in.
• Min. Bend/Installation: 1.900 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMR, CMX-Outdoor
• CEC/C(UL) Specification: CMR, CMX-Outdoor
• EU Directive 2011/65/EU (ROHS II): Yes
• IEEE Specification: 802.3 10BaseT, 100BaseT4
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/10/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: NEMA WC-63 Category 3, Verified to ANSI/TIA-586-C.2, Category 3

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 15
• Maximum Capacitance Unbalance (pF/100m): 330
• Nominal Velocity of Propagation: VP (%): 70
• Maximum Delay (ns/100 m): 538 @ 100MHz
• Max. Delay Skew (ns/100 m): 45
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 9.38
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 5

Flame Test:
• UL Flame Test: UL1666 Vertical Riser
• C(UL) Flame Test: FT4
• CSA Flame Test: FT4

Plenum/Non-Plenum:
• Plenum (Y/N): No
• Plenum Number: 1245A2

technical specification:
awg 24
# pairs 4
stranding solid
no. of conductors 8
conductor material bare copper
outer shield - type -
outer shield - material unshielded
overall cable - nominal diameter (in.) -
belden cable part number 1229A1