Description:
• Industry Standard SMPTE 311M Cable, 4 power conductors, 2 SM fibers w/24 and 20 AWG stranded (7x32 and 19x32) TC conductors, PVC insulation, TC braid shield (95% coverage), CPE jacket.
Insulation:
• Materials: PVC - Polyvinyl Chloride (20 AWG and 24 AWG)
• Diameters (in.): 0.063 (20 AWG) and 0.050 (24 AWG)
Outer Jacket:
• Trade Name: Belflex®
• Material: PVC Blend - Polyvinyl Chloride Blend
Strength Member:
• Overall Strength Member Diameter: 0.089
• Material: 302 Stainless Steel
Fiber:
Physical Characteristics:
• Fiber Type: Single Mode/125/900 Micron
• Number of Fibers: 2
• Mode Field Diameter @ 1310nm: 9.5 +/-1 microns
• Clad Diameter: 125 microns
• Core-clad Concentricity Error: < to 1 micron
• Primary Coating Material: Acrylate
• Buffer Tube Diameter: 900 microns
• Buffer Tube Material: PVC - Polyvinyl Chloride
Optical Characteristics:
• Maximum Attenuation @ 1310nm: 0.5 dB/km
• Maximum Attenuation @ 1550nm: 0.5 dB/km
Usage (Overall):
Applications:
• SMPTE 311M Camera Cable
Mechanical Charactertistics (Overall):
• Operating Tempeature Range: -40°C To +75°C
• Max. Recommended Pulling Tension: 450 lbs.
• Min. Bend Radius/Minor Axis: 2.500 in.
• Flex Cycle Rating: UL1581, Sec. 1582: 15,000 Cycles @ 3.6
• Crush Resistance: Compression, FOTP-41: 397 lbs.
• Impact Resistance: FOTP-25: 20 Cycles @ 1.32 lbs.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMR
• CEC/C(UL) Specification: CMG
•UL Rating: CMR-OF
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 07/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: SMPTE 311
Electrical Characteristics (Individual Shield):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 23.300 (24 AWG)
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 8.800 (20 AWG)
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 3.500
Flame Test:
• UL Flame Test: UL1666 Vertical Shaft
• CSA Flame Test: FT4
• IEEE Flame Test: 1202
Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Suggested Connectors: SMPTE 304M Connectors
Plenum/Non-Plenum:
• Plenum (Y/N): No
• Plenum Number: 7804P
technical specification: | |
awg | 24 and 20 |
# conductors | 2 and 4 |
stranding | 7x32 and 19x32 |
conductor material | tinned copper |
dia. (in.) | 0.024 and 0.037 |
outer shield - type | braid |
outer shield - material | tinned copper |
overall cable- nominal dia. (in.) | 0.362 |
belden cable part number | 7804R |