Belden 580902 19 AWG 5 Pairs Spec 20-2 Communications Stranded Cable
Select gauge from drop-down menu for prices:
- Belden IMSA Spec 20-2 Aerial and Duct 600V Signal and Communications Cable
- Belden 601622 19 AWG 6 Pairs Spec 20-2 Communications Solid Cable
- Belden 601530 19 AWG 6 Pairs Spec 20-2 Communications Stranded Cable
- Belden 601510 16 AWG 3 Pairs Spec 20-2 Communications Solid Cable
- Belden 601227 16 AWG 6 Pairs Spec 20-2 Communications Solid Cable
- Belden 601446 16 AWG 12 Pairs Spec 20-2 Communications Solid Cable
- Belden 601428 16 AWG 25 Pairs Spec 20-2 Communications Solid Cable
- Belden 601481 14 AWG 3 Pairs Spec 20-2 Communications Solid Cable
- Belden 603723 14 AWG 4 Pairs Spec 20-2 Communications Solid Cable
- Belden 601617 14 AWG 6 Pairs Spec 20-2 Communications Solid Cable
Description:
• 19 AWG stranded (7x27) bare copper conductors, HDPE insulation, corrugated copper tape, LDPE jacket.
Insulation:
• Material: HDPE - High Density Polyethylene
Outer Jacket:
• Material: LDPE - Low Density Polyethylene
• Nom. Wall Thickness (mm): 1.524
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +80°C
• Bulk Cable Weight: 205.372 Kg/Km
• Max. Recommended Pulling Tension: 778.435 N
• Min. Bend Radius/Minor Axis: 152.400 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• IMSA Specification: 20-2
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 27.2323
Suitability:
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 19 |
# pairs | 5 |
solid or stranded | 7 strand |
no. of conductors | 10 |
conductor material | bare copper |
outer shield - type | tape |
outer shield - material | corrugated copper tape |
overall cable- nominal dia. (mm) | 15.240 |
belden cable part number | 580902 |