Belden 123084A Cable 22 AWG and 24 AWG 1 Pair DeviceNet Multi Conductor DeviceBus For ODVA Shielded Gray or Red PVC Jacket 300V Cable

Belden 123084A Cable 22 AWG and 24 AWG 1 Pair DeviceNet Multi Conductor DeviceBus For ODVA Shielded Gray or Red PVC Jacket 300V Cable

Select gauge from drop-down menu for prices:

Belden 123084A Cable 22 AWG and 24 AWG 1 Pair DeviceNet Multi Conductor DeviceBus For ODVA Shielded Gray or Red PVC Jacket 300V Cable
Belden 123084A Cable 22 AWG and 24 AWG 1 Pair DeviceNet Multi Conductor DeviceBus For ODVA Shielded Gray or Red PVC Jacket 300V Cable

Description:
• 22 and 24 AWG stranded tinned copper conductors, PVC insulation (power), FPE insulation (Data), individually foil shielded (100% coverage) and an overall tinned copper braid (65% coverage), Gray or Red sunlight/oil-resistant PVC jacket.

Insulation:
• Material: PVC - Polyvinyl Chloride (22 AWG)
• Material: FPE - Foam Polyethylene (24 AWG)

Inner Shield:
• Material: Aluminum Foil-Polyester Tape (22 AWG Pair and 24 AWG Pair)

Outer Shield Drain Wire AWG:
• AWG: 22
• Stranding: 19x34
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (in.): 0.032

Mechanical Characteristics (Overall):
• Operating Temperature Range: -20°C To +75°C
• UL Temperature Rating: 75°C
• Bulk Cable Weight: 41 lbs/1000 ft.
• Max. Recommended Pulling Tension: 65 lbs.
• Min. Bend Radius/Minor Axis: 2.750 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CL2, CMG
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 20201 (600 V 75°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: ODVA Class 2 Thin

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 120 (24 AWG Pair)
• Nom. Inductance (μH/ft): 0.221 (22 AWG Pair)
• Nom. Inductance (μH/ft): 0.251 (24 AWG Pair)
• Nom. Capacitance Conductor to Conductor (pF/ft): 12.0 (24 AWG Pair)
• Nominal Velocity of Propagation: VP (%): 75 (24 AWG Pair)
• Maximum Delay (ns/ft): 1.36 (24 AWG Pair)
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 17.5 (22 AWG)
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 28.0 (24 AWG)
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 3.2
• Max. Operating Voltage - UL: 300 V RMS (CL2, CMG)
• Max. Operating Voltage - UL: 300 V RMS (C/UL) AWM)
• Max. Operating Voltage - UL: 600 V RMS (UL AWM Style 20201)
• Max. Recommended Current: 1.7 Amps/Conductor @ 25°C (24 AWG)
• Max. Recommended Current: 4 Amps/Conductor @ 24 V per NEC CL2 (Power Pair)

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4

Suitability:
• Sunlight Resistance: Yes
• Oil Resistance: Yes

Plenum/Non-Plenum:
• Plenum(Y/N): No

technical specification:
awg 22 and 24
# pairs 1
stranding 19x34 and 19x36
no. of conductors 4
conductor material tinned copper
diameter (in.) -
outer shield - type braid
outer shield - material tinned copper
overall cable - nominal diameter (in.) 0.280
belden cable part number 123084A

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question