Belden 1269A Cable 22 AWG 2 Pairs RS-485 Low Capacitance Computer and Computer P.O.S. Multi Conductor Solid Plenum FEP Jacket Cable

Belden 1269A Cable 22 AWG 2 Pairs RS-485 Low Capacitance Computer and Computer P.O.S. Multi Conductor Solid Plenum FEP Jacket Cable

Select gauge from drop-down menu for prices:

Belden 1269A Cable 22 AWG 2 Pairs RS-485 Low Capacitance Computer and Computer P.O.S. Multi Conductor Solid Plenum FEP Jacket Cable
Belden 1269A Cable 22 AWG 2 Pairs RS-485 Low Capacitance Computer and Computer P.O.S. Multi Conductor Solid Plenum FEP Jacket Cable

Description:
• 22 AWG solid TC conductors, plenum, solid FEP insulation, twisted pairs, overall Beldfoil (100% coverage) + TC braid shield (90% coverage), 22 AWG solid TC drain wire, FEP jacket.

Insulation:
• Material: Solid FEP - Solid Fluorinated Ethylene Propylene
• Nom. Wall Thickness (in.): 0.016

Outer Shield Drain Wire AWG:
• AWG: 22
• Stranding: Solid
• Material: TC - Tinned Copper
• Outer Shield Separator Material: Polyester Tape

Outer Jacket:
• Material: FEP - Fluorinated Ethylene Propylene
• Nom. Wall Thickness (in.): 0.017

Mechanical Characteristics (Overall):
• Operating Temperature Range: -70°C To +200°C
• Bulk Cable Weight: 44 lbs/1000 ft.
• Max. Recommended Pulling Tension: 88 lbs.
• Min. Bend Radius/Minor Axis: 2.500 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP, MPP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 100
• Nom. Inductance (μH/ft): 0.17
• Nom. Capacitance Conductor to Conductor (pF/ft): 15.5
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 27
• Nominal Velocity of Propagation: VP (%): 69.5
• Nominal Delay (ns/ft): 1.46
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 16.5
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 2.1
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 2.3 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: NFPA 262
• CSA Flame Test: FT6

Plenum/Non-Plenum:
• Plenum(Y/N): Yes
• Plenum Number: 1268A

technical specification:
awg 22
# pairs 2
stranding solid
no. of conductors 4
conductor material tinned copper
diameter (in.) -
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable - nominal diameter (in.) 0.240
belden cable part number 1269A