Description:
• Tinned copper conductor, PVC insulation. Rated 105ºC, 600V.
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (in.): 0.030
Mechanical Characteristics (Overall):
• Operating Temperature Range: -30°C To +105°C
• Bulk Cable Weight: 13.750 lbs/1000 ft.
• Min. Bend Radius/Minor Axis: 1 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• UL Rating: 600 V, 105°C
• UL Type: MTW or AWM 1015/1230
• CSA Rating: 600 V, 105°C
• CSA Type: AWM I A/B or TEW
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 07/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 3.750
• Max. Operating Voltage - UL: 600 V RMS
• Max. Recommended Current: 26 Amps(Single conductor in free air @ 30C ambient)
Flame Test:
• UL Flame Test: VW-1
• CSA Flame Test: FT1
Plenum/Non-Plenum:
• Plenum(Y/N): No
technical specification: | |
awg | 16 |
# pairs | - |
stranding | 26x30 |
no. of conductors | 1 |
conductor material | tinned copper |
outer shield - type | - |
outer shield - material | unsheilded |
overall cable - nominal diameter (in.) | 0.123 |
belden cable part number | 8917 |