Belden 9696 Cable 22 AWG 2 Pairs RS-485 Computer P.O.S. Multi Conductor Solid Bare Copper PVC Jacket Cable

Belden 9696 Cable 22 AWG 2 Pairs RS-485 Computer P.O.S. Multi Conductor Solid Bare Copper PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 9696 Cable 22 AWG 2 Pairs RS-485 Computer P.O.S. Multi Conductor Solid Bare Copper PVC Jacket Cable
Belden 9696 Cable 22 AWG 2 Pairs RS-485 Computer P.O.S. Multi Conductor Solid Bare Copper PVC Jacket Cable

Description:
• 22 AWG solid BC conductors, polyethylene insulation, twisted pairs, overall Beldfoil® shield (100% coverage) + TC braid (58% coverage), 22 AWG solid TC drain wire, PVC jacket.

Insulation:
• Material: PE - Polyethylene

Outer Shield Drain Wire AWG:
• AWG: 22
• Stranding: Solid
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride

Mechanical Characteristics (Overall):
• Operating Temperature Range: -30°C To +80°C
• Non-UL Temperature Rating: 80°C
• Bulk Cable Weight: 62 lbs/1000 ft.
• Max. Recommended Pulling Tension: 64 lbs.
• Min. Bend Radius/Minor Axis: 3 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM
• CEC/C(UL) Specification: CM
• AWM Specification: UL Style 2919 (30 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 100
• Nom. Capacitance Conductor to Conductor (pF/ft): 16
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 27.5
• Nominal Velocity of Propagation: VP (%): 66
• Nominal Delay (ns/ft): 1.54
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 14.2
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 4.2
• Max. Operating Voltage - UL: 300 V RMS

Flame Test:
• UL Flame Test: UL1685 UL Loading

Plenum/Non-Plenum:
• Plenum(Y/N): No
• Plenum Number: 89696

technical specification:
awg 22
# pairs 2
stranding solid
no. of conductors 4
conductor material bare copper
diameter (in.) -
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable - nominal diameter (in.) 0.290
belden cable part number 9696