Belden 1334A Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 Oil-Resistant PVC Jacket Cable

Belden 1334A Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 Oil-Resistant PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 1334A Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 Oil-Resistant PVC Jacket Cable

Regular price $4.02 $2.80 Sale /per Foot

Belden 1334A Cable 18 AWG 1 Pair Foundation Fieldbus or ProfiBus DataBus ISA/SP-50 Multi Conductor Stranded 7x26 Oil-Resistant PVC Jacket Cable

Description:
• 1 pair, 18 AWG stranded (7x26) tinned copper conductors, polyolefin insulation, Beldfoil® shield (100% coverage) plus a tinned copper braid shield (65% coverage), tinned copper drain wire, oil-resistant PVC jacket.

Insulation:
• Material: PO - Polyolefin

Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Drain Wire Conductor Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Outer Jacket over Armor (y/n): Y

Outer Jacket over Armor:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness: 0.055

Armor:
• Armor Type: Continuously Corrugated
• Armor Material: Aluminum
• Armor Thickness: 0.025
• Diameter over Armor: 0.455

Mechanical Characteristics (Overall):
• Operating Temperature Range: -40°C To +105°C
• UL Temperature Rating: 105°C
• Bulk Cable Weight: 145 lbs/1000 ft.
• Max. Recommended Pulling Tension: 59 lbs.
• Min. Bend Radius/Minor Axis: 6.800 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: ITC, PLTC
• CEC/C(UL) Specification: CM
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/18/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Unaveraged Impedance (Ohm): 100.000
• Nom. Inductance (μH/ft): 0.19
• Nom. Capacitance Conductor to Shield (pF/ft): 45.0
• Nom. Mutual Capacitance (pF/ft): 24.0
• Maximum Capacitance Unbalance (pF/ft): 1.200
• Nominal Velocity of Propagation: VP (%): 66
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 5.86
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 7.500
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 5.2 Amps/Conductor

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• IEC Flame Test: 60332-3-24 (Category C)
• IEEE Flame Test: 1202

Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum(Y/N): No

technical specification:
awg 18
# pairs 1
stranding 7x26
no. of conductors 2
conductor material tinned copper
diameter (in.) 0.048
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable - nominal diameter (in.) 0.287
belden cable part number 1334A

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question