Belden 3077F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x30 PVC Jacket Cable

Belden 3077F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x30 PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 3077F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x30 PVC Jacket Cable

Regular price $1.00 Sale /per Foot

Belden 3077F Cable 22 AWG 1 Pair Foundation Fieldbus DataBus ISA/SP-50 Multi Conductor Stranded 7x30 PVC Jacket Cable

Description:
• 22 AWG stranded (7x30) tinned copper conductors, polyolefin insulation, Beldfoil® shield (100% coverage), tinned copper drain wire, PVC jacket.

Insulation:
• Material: PO - Polyolefin

Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Drain Wire Conductor Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride

Mechanical Characteristics (Overall):
• Operating Temperature Range: -30°C To +105°C
• UL Temperature Rating: 105°C
• Bulk Cable Weight: 18 lbs/1000 ft.
• Max. Recommended Pulling Tension: 27 lbs.
• Min. Bend Radius/Minor Axis: 2.200 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM, ITC, PLTC
• NEC Articles: 725, 727, 800
• CEC/C(UL) Specification: CM
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Unaveraged Impedance (Ohm): 100
• Nom. Inductance (μH/ft): 0.20
• Nom. Capacitance Conductor to Shield (pF/ft): 44.0
• Nom. Mutual Capacitance (pF/ft): 23.5
• Maximum Capacitance Unbalance (pF/ft): 1.2
• Nominal Velocity of Propagation: VP (%): 66
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 17.1
• Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 11.400 Ohm/1000 ft
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 2.5 Amps/Conductor

Flame Test:
• UL Flame Test: UL1685 UL Loading
• CSA Flame Test: FT4

Plenum/Non-Plenum:
• Plenum(Y/N): No

technical specification:
awg 22
# pairs 1
stranding 7x30
no. of conductors 2
conductor material tinned copper
diameter (in.) 0.030
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable - nominal diameter (in.) 0.196
belden cable part number 3077F

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question