Belden 1118A 16 AWG 1 Pair 600V Multi Conductor BC Tray Cable
Select gauge from drop-down menu for prices:
- Belden 16 AWG Pairs Overall Beldfoil Shielding UL Instrumentation 600V Bare Copper Tray Cable
- Belden 3090A 16 AWG 1 Pair 600V Multi Conductor BC PVC Jacket Tray Cable
- Belden 1069A 16 AWG 2 Pairs 600V Multi Conductor BC Tray Cable
- Belden 1527A 16 AWG 3 Pairs 600V Multi Conductor BC Tray Cable
- Belden 1070A 16 AWG 4 Pairs 600V Multi Conductor BC Tray Cable
- Belden 1071A 16 AWG 8 Pairs 600V Multi Conductor BC Tray Cable
- Belden 1072A 16 AWG 12 Pairs 600V Multi Conductor BC Tray Cable
- Belden 1073A 16 AWG 16 Pairs 600V Multi Conductor BC Tray Cable
- Belden 1074A 16 AWG 24 Pairs 600V Multi Conductor BC Tray Cable
- Belden 1089A 16 AWG 36 Pairs 600V Multi Conductor BC Tray Cable
- Belden 1090A 16 AWG 50 Pairs 600V Multi Conductor BC Tray Cable
Product Details
Description:
• 16 AWG pairs stranded (7x24) bare copper conductors, twisted pairs, PVC/Nylon insulation, overall Beldfoil shield (100% coverage), PVC jacket.
Insulation:
• Material: PVC/Nylon - Polyvinyl Chloride/Nylon
Outer Shield Drain Wire AWG:
• AWG: 18
• Stranding: 7x26
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.1938
• Outer Jacket Ripcord: Yes
Mechanical Charactertistics (Overall):
• Wet Temperature Range: -30°C To +75°C
• Dry Temperature Range: -30°C To +90°C
• Bulk Cable Weight: 46 lbs/1000 ft.
• Max. Recommended Pulling Tension: 40 lbs.
• Min. Bend Radius/Minor Axis: 1.200 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: NPLF, TC
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: ICEA S-73-532, S-61-402
Electrical Characteristics (Overall):
• Nom. Inductance (?H/ft): 0.20
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 4.200
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 5.070
• Max. Operating Voltage - UL: 600 V RMS (NEC Type TC)
• Max. Operating Voltage - UL: 150 V RMS (NPLF)
• Max. Recommended Current: 8 Amps/conductor @ 25°C
Flame Test:
• UL Flame Test: UL1685 Vertical Tray Flame Test
• CSA Flame Test: FT4
• IEEE Flame Test: 1202
Suitability:
• Suitability - Burial: Yes
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 16 |
# paris | 1 |
stranding | 7x24 |
no. of conductors | 2 |
conductor material | bare copper |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape |
overall cable- nominal dia. (mm) | 7.620 |
belden cable part number | 1118A |