Belden 25500 18 AWG 1 Triad 600V ACIC Armored Steel Cable
Select gauge from drop-down menu for prices:
- Belden 18 AWG CSA Instrumentation 600V ACIC Armored Individually and Overall Beldfoil Shielded Triads 7x26 Cable
- Belden 24516 18 AWG 1 Triad 600V ACIC Armored Aluminum Cable
- Belden 24517 18 AWG 2 Triads 600V ACIC Armored Aluminum Cable
- Belden 24518 18 AWG 4 Triads 600V ACIC Armored Aluminum Cable
- Belden 24519 18 AWG 8 Triads 600V ACIC Armored Aluminum Cable
- Belden 25522 18 AWG 2 Triads 600V ACIC Armored Steel Cable
- Belden 25520 18 AWG 4 Triads 600V ACIC Armored Steel Cable
- Belden 25523 18 AWG 8 Triads 600V ACIC Armored Steel Cable
Description:
• 18 AWG triads stranded (7x26) tinned copper conductors, individual Beldfoil plus a polyester isolation tape, PVC insulation, PVC inner jacket, overall Beldfoil shield (100% coverage), interlocked armor, PVC outer jacket.
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.762
Inner Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 8.636
Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 16.002
• Outer Jacket Ripcord: Yes
Armor:
• Armor Type: Interlocked
• Armor Material: Steel
Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +105°C
• Wet Temperature Range: -40°C To +75°C
• Dry Temperature Range: -40°C To +105°C
• Bulk Cable Weight: 276 lbs/1000 ft.
• Max. Recommended Pulling Tension: 80 lbs.
• Min. Bend Radius/Minor Axis: 7.600 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2#239, Type ACIC, C22.2#174, HLBCD, C22.2#0.3, Clause 4.31 Low Acid Test
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: Low Acid Test
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 5.86
• Max. Operating Voltage - Other: 600 (CEC ACIC)
Flame Test:
• CSA Flame Test: FT4
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 18 |
# triads | 1 |
stranding | 7x26 |
no. of conductors | 3 |
conductor material | tinned copper |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape |
overall cable- nominal dia. (mm) | 16.002 |
belden cable part number - steel | 25500 |