Belden 1213A 26 AWG 8 Conductors Computers Instrumentation and Medical Elec Interconnect Multi Conductor Overall Shield Cable
Select gauge from drop-down menu for prices:
- Belden Cable Data Cables for Molex Semmconn and AMP SDL Connectors Multi Conductor Overall Shield Cable
- Belden 1211A Cable 26 AWG 4 Conductors Computers Instrumentation and Medical Elec Interconnect Multi Conductor Overall Shield Cable
- Belden 1212A Cable 26 AWG 6 Conductors Computers Instrumentation and Medical Elec Interconnect Multi Conductor Overall Shield Cable
- Belden 1214A Cable 26 AWG 16 Conductors Computers Instrumentation and Medical Elec Interconnect Multi Conductor Overall Shield Cable
Description:
• 26 AWG stranded (7x34) TC conductors, PVC insulation, Duofoil® shield (100% coverage), 26 AWG stranded TC drain wire, PVC jacket.
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.381
Outer Shield Drain Wire AWG:
• AWG: 26
• Stranding: 7x34
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.9906
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +90°C
• Non-UL Temperature Rating: 90°C
• Bulk Cable Weight: 21 lbs/1000 ft.
• Max. Recommended Pulling Tension: 32 lbs.
• Min. Bend Radius/Minor Axis: 2.500 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CL2X
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 10/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Conductor (pF/ft): 26
• Nominal Velocity of Propagation (VP %): 60
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 37.3
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 1.2 Amps/Conductor @ 25°C (10°C rise in temp)
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 26 |
# conductors | 8 |
stranding | 7x34 |
no. of conductors | 8 |
conductor material | tinned copper |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape-aluminum foil |
overall cable- nominal dia. (mm) | 6.0706 |
belden cable part number | 1213A |