• 22 AWG stranded (7x30) tinned copper conductors, conductors cabled, PVC insulation, PVC Jacket.

Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.279

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.8128

Mechanical Charactertistics (Overall):
• Operating Tempeature Range: -20°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 2576)
• Bulk Cable Weight: 47 lbs/1000 ft.
• Max. Recommended Pulling Tension: 110 lbs.
• Min. Bend Radius/Minor Axis: 2.750 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2576 (150 V 80°C)
• CSA Specification: FT4
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Inductance (μH/ft): 0.17
• Nom. Capacitance Conductor to Conductor (pF/ft): 34
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 15.6
• Max. Operating Voltage - UL: 300 V RMS (CMG)
• Max. Operating Voltage - UL: 150 V RMS (UL AWM Style 2576)
• Max. Recommended Current: 2.1 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 22
# conductors 12
stranding 7x30
no. of conductors 12
conductor material tinned copper
dia. (mm) -
outer shield - material unshielded
overall cable- nominal dia. (mm) 6.9088
belden cable part number 8457

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question