Belden 88770 Cable 18 AWG 3 Conductors Audio Control and Instrumentation Overall Beldfoil Shield FEP Jacket Cable
Select gauge from drop-down menu for prices:
- Belden Cable 18 AWG Audio Control and Instrumentation Overall Beldfoil Shield Non Plenum Cable
- Belden 8770 18 AWG 3C Beldfoil Shield Instrumentation Cable
- Belden 9418 Cable 18 AWG 4 Conductors Audio Control and Instrumentation Overall Beldfoil Shield Non Plenum Cable
- Belden 89418 Cable 18 AWG 4 Conductors Audio Control and Instrumentation Overall Beldfoil Shield FEP Jacket Cable
- Belden 82418 Cable 18 AWG 4 Conductors Audio Control and Instrumentation Overall Beldfoil Shield Flamarrest Jacket Cable
Description:
• 18 AWG stranded (19x30) TC conductors, conductors cabled, plenum, FEP insulation, overall Beldfoil® shield (100% coverage), 20 AWG stranded TC drain wire, FEP jacket.
Insulation:
• Material: FEP - Fluorinated Ethylene Propylene
• Wall Thickness (mm): 0.1778
Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: 19x32
• Material: TC - Tinned Copper
Outer Jacket:
• Material: FEP - Fluorinated Ethylene Propylene
• Nom. Wall Thickness (mm): 0.3556
Overall Cabling Lay Length and Direction:
• Length (mm): 44.450
• Twists (twist/m): 22.639 (Left Hand Direction)
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -70°C To +200°C
• Bulk Cable Weight: 41.670 Kg/Km
• Max. Recommended Pulling Tension: 329.167 N
• Min. Bend Radius/Minor Axis: 44.450 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• NEC Articles: 800
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Conductor (pF/m): 177.174
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 314.976
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 20.9984
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 23.9513
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 8 Amps/Conductor @ 25°C ambient (35C Temp. Rise)
Flame Test:
• UL Flame Test: NFPA 262
• CSA Flame Test: FT6
Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Suitability - Burial: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): Yes
• Non-Plenum Number: 8770
technical specification: | |
awg | 18 |
# conductors | 3 |
stranding | 19x30 |
no. of conductors | 3 |
conductor material | tinned copper |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape w/shorting fold |
overall cable- nominal dia. (mm) | 3.937 |
belden cable part number | 88770 |