Belden 8473 Cable 14 AWG 1 Pair Unshielded Plenum Rated Audio Control and Instrumentation PVC Jacket Cable
Select gauge from drop-down menu for prices:
- Belden Cable Unshielded Plenum and Non Plenum Rated Audio Control and Instrumentation Multi Conductor Paired Cable
- Belden 89740 Cable 18 AWG 1 Pair Unshielded Plenum Rated Audio Control and Instrumentation FEP Jacket Cable
- Belden 87740 Cable 18 AWG 1 Pair Unshielded Plenum Rated Audio Control and Instrumentation PVDF Jacket Cable
- Belden 82740 Cable 18 AWG 1 Pair Unshielded Plenum Rated Audio Control and Instrumentation Flamarrest Jacket Cable
- Belden 8471 Cable 16 AWG 1 Pair Unshielded Plenum Rated Audio Control and Instrumentation PVC Jacket Cable
- Belden 8477 Cable 12 AWG 1 Pair Unshielded Plenum Rated Audio Control and Instrumentation PVC Jacket Cable
Description:
• 14 AWG stranded (42x30) tinned copper conductors, PVC insulation, twisted pair, PVC jacket.
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.813
• Insulation Resistance: 1000 Megohms/1000 ft. @ 500 VDC
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.016
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +90°C
• Bulk Cable Weight: 86.316 Kg/Km
• Max. Recommended Pulling Tension: 418.131 N
• Min. Bend Radius/Minor Axis: 88.900 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CL3
• AWM Specification: UL Style 2587 (600 V 90°C)
• CSA Specification: FAS90
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Inductance (μH/m): 0.62339
• Nom. Capacitance Conductor to Conductor (pF/m): 72.182
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 9.38366
• Max. Operating Voltage - UL: 600 V RMS (UL AWM Style 2587)
• Max. Operating Voltage - UL: 300 V RMS (CL3)
• Max. Recommended Current: 9.6 Amps/Conductor @ 25°C (10°C rise in temp)
Flame Test:
• UL Flame Test: UL1685 UL Loading
• CSA Flame Test: FT1
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 14 |
# pairs | 1 |
stranding | 42x30 |
no. of conductors | 2 |
conductor material | tinned copper |
outer shield - material | unshielded |
overall cable- nominal dia. (mm) | 9.042 |
belden cable part number | 8473 |