Belden 89505 Cable 24 AWG 5 Pairs Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application FEP Jacket Cable
Select gauge from drop-down menu for prices:
- Belden Cable Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application Multi Conductor Paired Cable
- Belden 82641 Cable 24 AWG 1 Pair Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 82502 Cable 24 AWG 2 Pairs Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 82503 Cable 24 AWG 3 Pairs Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 82504 Cable 24 AWG 4 Pairs Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 82505 Cable 24 AWG 5 Pairs Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 82506 Cable 24 AWG 6 Pairs Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 82509 Cable 24 AWG 9 Pairs Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application Multi Conductor Cable
- Belden 88641 Cable 24 AWG 1 Pair Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application FEP Jacket Cable
- Belden 89503 Cable 24 AWG 3 Pairs Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application FEP Jacket Cable
- Belden 89504 Cable 24 AWG 4 Pairs Overall Beldfoil Shield Plenum Rated Computer Cables for EIA RS-232 Application FEP Jacket Cable
Description:
• 24 AWG stranded (7x32) tinned copper conductors, plenum, FEP insulation, twisted pair, overall Beldfoil shield (100% coverage), 24 AWG stranded TC drain wire, FEP jacket.
Insulation:
• Material: FEP - Fluorinated Ethylene Propylene
• Wall Thickness (mm): 0.1524
Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: 7x32
• Material: TC - Tinned Copper
Outer Jacket:
• Material: FEP - Fluorinated Ethylene Propylene
• Nom. Wall Thickness (mm): 0.3356
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -70°C To +200°C
• Bulk Cable Weight: 44.646 Kg/Km
• Max. Recommended Pulling Tension: 271.340 N
• Min. Bend Radius/Minor Axis: 50.800 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Inductance (μH/m): 0.55777
• Nom. Capacitance Conductor to Conductor (pF/m): 68.901
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 131.24
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 79.0721
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 49.215
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 1.5 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: NFPA 262
• CSA Flame Test: FT6
Plenum/Non-Plenum:
• Plenum (Y/N): Yes
• Non-Plenum Number: 9505
technical specification: | |
awg | 24 |
# pairs | 5 |
stranding | 7x32 |
no. of conductors | 10 |
conductor material | tinned copper |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape |
overall cable- nominal dia. (mm) | 5.004 |
belden cable part number | 89505 |