Belden 9460 Cable 18 AWG 1 Pair Overall Beldfoil Shield Audio Control and Instrumentation Stranded 16x30 TC PVC Jacket Cable

Belden 9460 Cable 18 AWG 1 Pair Overall Beldfoil Shield Audio Control and Instrumentation Stranded 16x30 TC PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 9460 Cable 18 AWG 1 Pair Overall Beldfoil Shield Audio Control and Instrumentation Stranded 16x30 TC PVC Jacket Cable

Regular price $3.51 $2.34 Sale /per Foot

Belden 9460 Cable 18 AWG 1 Pair Overall Beldfoil Shield Audio Control and Instrumentation Stranded 16x30 TC PVC Jacket Cable

Description:
• 18 AWG stranded (16x30) TC conductors, polyethylene insulation, twisted pair, overall Beldfoil® shield (100% coverage), 20 AWG stranded TC drain wire, PVC jacket.

Insulation:
• Material: PE - Polyethylene
• Wall Thickness (mm): 0.4572

Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: Stranded
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.762

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +60°C
• UL Temperature Rating: 60°C (UL AWM Style 2092)
• Bulk Cable Weight: 34 lbs/1000 ft.
• Max. Recommended Pulling Tension: 70 lbs.
• Min. Bend Radius/Minor Axis: 2.500 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM
• CEC/C(UL) Specification: CM
• AWM Specification: UL Style 2092 (300 V 60°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 57
• Nom. Inductance (μH/ft): 0.18
• Nom. Capacitance Conductor to Conductor (pF/ft): 29.8
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 44
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 6.5
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 5.2 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 UL Loading

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 18
# pairs 1
stranding 16x30
no. of conductors 2
conductor material tinned copper
outer shield - type tape
outer shield - material aluminum foil-polyester tape
overall cable- nominal dia. (mm) 5.842
belden cable part number 9460

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.