Belden 9508 Cable 24 AWG 8 Pairs Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable

Belden 9508 Cable 24 AWG 8 Pairs Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable

Select gauge from drop-down menu for prices:

Belden 9508 Cable 24 AWG 8 Pairs Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable

Regular price $7.46 $4.97 Sale /per Foot

Belden 9508 Cable 24 AWG 8 Pairs Overall Beldfoil Shield Computer Cables for EIA RS-232 Application Multi Conductor Cable

Description:
• 24 AWG stranded (7x32) TC conductors, semi-rigid PVC insulation, twisted pairs, overall Beldfoil shield (100% coverage), 24 AWG stranded TC drain Wire (continued), PVC jacket.

Insulation:
• Material: S-R PVC - Semi-Rigid Polyvinyl Chloride
• Wall Thickness (mm): 0.279

Outer Shield Drain Wire AWG:
• AWG: 24
• Stranding: 7x32
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.813

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +80°C
• Non-UL Temperature Rating: 80°C (UL AWM Style 2464)
• Bulk Cable Weight: 56 lbs/1000 ft.
• Max. Recommended Pulling Tension: 88 lbs.
• Min. Bend Radius/Minor Axis: 3.250 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2464 (300 V 80°C)
• CSA Specification: AWM I A
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Conductor (pF/ft): 30
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/ft): 50
• Nominal Velocity of Propagation (VP %): 60
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 24
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 16.5
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 1.1 Amps/Conductor @ 25°C

Flame Test:
• C(UL) Flame Test: FT4

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 24
# pairs 8
stranding 7x32
no. of conductors 16
conductor material tinned copper
outer shield - type tape
outer shield - material aluminum foil-polyester tape w/shorting fold
overall cable- nominal dia. (mm) 8.230
belden cable part number 9508

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question