Service Wire 3 AWG XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT3BK
Select gauge from drop-down menu for prices:
- Service Wire XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable
- Service Wire 14 AWG XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT14BK
- Service Wire 12 AWG XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT12BK
- Service Wire 10 AWG XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT10BK
- Service Wire 8 AWG XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT8BK
- Service Wire 6 AWG XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT6BK
- Service Wire 4 AWG XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT4BK
- Service Wire 2 AWG XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT2BK
- Service Wire 1 AWG XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT1BK
- Service Wire 1/0 AWG XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT1/0BK
- Service Wire 2/0 AWG XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT2/0BK
- Service Wire 3/0 AWG XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT3/0BK
- Service Wire 4/0 AWG XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT4/0BK
- Service Wire 250 MCM XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT250BK
- Service Wire 300 MCM XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT300BK
- Service Wire 350 MCM XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT350BK
- Service Wire 400 MCM XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT400BK
- Service Wire 500 MCM XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT500BK
- Service Wire 600 MCM XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT600BK
- Service Wire 750 MCM XHHW-2 VW-1 Tinned CT Rated 600 Volt Copper Cable XHVWT750BK
Description: Single tinned copper conductor, stranded and insulated with moisture, heat and flame resistant, chemically crosslinked polyethylene. Available in colors.
Application: Suitable for general purpose wiring, for power distribution and branch circuit wiring, where a cable having superior flame retardance is required. Suitable for use in 105º dry systems. Also suitable for use in low leakage circuits requiring a dielectric constant of 3.5 or less (Hospital Grade).
Standards:
ASTM Standards:
• B-3 (soft or annealed)
• B-8 (concentric lay stranded)
• B-33 (tinned)
• B787 (combination strand)
• UL 44
• C(UL) US RW90:CSA/UL Listed
• ICEA S-95-658/NEMA WC-70
• Federal Spec. A-A-59544
• Flame Rated: CT Use/IEEE1202 (1/0 AWG and larger)
• FT-4 (1/0 AWG and larger)
• Temperature Rated at 90°C Wet/Dry
• Cold Temperature Rated at -40°C
• Sunlight Resistant (#6 AWG and larger)
• Gasoline and Oil Resistant II
• Appliance Wiring Material: Style 3578
• RoHS Compliant
technical specification: | |
size awg or kcmil | 3 |
strand (no.) | 7 |
insulation thickness (mils) | 45 |
nominal diameter overall (inch) | 0.344 |
approx. net weight (lb/1000') | 185 |
ampacity* 90°c wet/dry | 165 |
service wire part number | XHVWT3BK |