Amercable CIR Power Cable 4/0 AWG 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-319
Select gauge from drop-down menu for prices:
- Amercable CIR Power Cable Gexol Insulated Arctic Grade With Ground 0.6/1kV Rated 90C
- Amercable CIR Power Cable 14 AWG 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-508
- Amercable CIR Power Cable 14 AWG 4 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-509
- Amercable CIR Power Cable 12 AWG 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-516
- Amercable CIR Power Cable 12 AWG 4 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-517
- Amercable CIR Power Cable 10 AWG 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-308
- Amercable CIR Power Cable 10 AWG 4 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-408
- Amercable CIR Power Cable 8 AWG 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-309
- Amercable 8 AWG 4C Gexol Insulated Arctic Grade With Ground 0.6/1kV Rated 90C CIR Power Cable 37-102-409
- Amercable CIR Power Cable 6 AWG 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-310
- Amercable CIR Power Cable 6 AWG 4 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-410
- Amercable CIR Power Cable 4 AWG 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-312
- Amercable CIR Power Cable 4 AWG 4 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-412
- Amercable CIR Power Cable 2 AWG 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-314
- Amercable CIR Power Cable 2 AWG 4 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-414
- Amercable CIR Power Cable 1/0 AWG 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-316
- Amercable CIR Power Cable 1/0 AWG 4 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-416
- Amercable CIR Power Cable 2/0 AWG 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-317
- Amercable CIR Power Cable 2/0 AWG 4 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-417
- Amercable CIR Power Cable 4/0 AWG 4 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-419
- Amercable CIR Power Cable 250MCM 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-330
- Amercable CIR Power Cable 250MCM 4 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-430
- Amercable CIR Power Cable 350MCM 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-331
- Amercable CIR Power Cable 350MCM 4 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-431
- Amercable CIR Power Cable 500MCM 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-333
- Amercable CIR Power Cable 500MCM 4 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-433
- Amercable CIR Power Cable 750MCM 3 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-334
- Amercable CIR Power Cable 750MCM 4 Conductors Gexol Insulated Arctic Grade Three and Four Conductor With Ground 0.6/1kV Rated 90C 37-102-434
Conductor: Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11.
Insulation: GEXOL® cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245. 600V/IEC 1000V.
Safer to Handle: CIR® has no sharp metal armor edges that imperil worker’s hands during splicing and installation of connectors
Jacket: A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoset compound meeting UL 1309/ CSA 245 and IEEE 1580.
Application: Designed and constructed to be a flexible alternative to Type MC cable where user desires crush and impact protection in arctic conditions.
Features:
• Complies with the requirements for TC-ER-HL per UL 2225*
• Exceeds CSA cold bend / cold impact (-40°C / -35°C)
• Gas & vapor tight – impervious to water and air
• Smaller bend radius (up to 40% smaller) than Type MC
• Reduced tray fill (up to 35% less) compared to Type MC
• Considerably more flexible than Type MC
• Reduced installation time and cost compared to Type MC
• Glands for this product cost up to 50% LESS than those for Type MC
CIR®Ratings & Approvals:
• 90°C temperature rating
• UL Listed as Marine Shipboard Cable (E111461)
• UL Listed as Type TC-ER
• UL Listed as TC-ER-HL (cables up to 1” in diameter)
• American Bureau of Shipping (ABS) (99-BT5905-X)
• Flame Retardant – IEEE 1202
• Suitable for use in Class I, Div 2 and Zone 2 environments
• Suitable for Class 1, Div 1 and Zone 1 environments (cables up to 1” in diameter)
technical specification: | |
conductor size(awg/kcmil) | 4/0 |
conductor size(mm2) | 109 |
number of conductors | 3 |
grounding conductor awg/kcmil | 4 |
nominal diameter(inches) | 1.769 |
weight(lbs/1000 ft.) | 3151 |
90°c nec ampacity | 260 |
75°c nec ampacity | 230 |
dc resistance at 25°c ampacity | 0.0585 |
ac resistance at 90°c, 60hz(ohms/1000 ft.) | 0.0753 |
inductive reactance(ohms/1000 ft.) | 0.0261 |
voltage drop (volts/amp/1000 ft.) | 0.131 |
amercable part number | 37-102-319CIRGAG |