Superior Essex Cable 26 AWG 132 Pair Switchboard 100 Ohm 200A / 800A Series Cable 55-H99-47
Select gauge from drop-down menu for prices:
- Superior Essex Cable 24 and 26 AWG Switchboard 100 Ohm 200A / 800A Series Cable
- Superior Essex Cable 24 AWG 6 Pair Switchboard 100 Ohm 200A / 800A Series Cable 55-399-46
- Superior Essex Cable 24 AWG 20 Pair Switchboard 100 Ohm 200A / 800A Series Cable 55-699-46
- Superior Essex Cable 24 AWG 101.5 Pair Switchboard 100 Ohm 200A / 800A Series Cable 55-E99-46
- Superior Essex Cable 24 AWG 24 Pair Switchboard 100 Ohm 200A / 800A Series Cable 55-N99-46
- Superior Essex Cable 24 AWG 36 Pair Switchboard 100 Ohm 200A / 800A Series Cable 55-P99-46
- Superior Essex Cable 26 AWG 17 Pair Switchboard 100 Ohm 200A / 800A Series Cable 55-599-47
- Superior Essex Cable 26 AWG 33 Pair Switchboard 100 Ohm 200A / 800A Series Cable 55-A99-47
- Superior Essex Cable 26 AWG 66 Pair Switchboard 100 Ohm 200A / 800A Series Cable 55-R99-47
- Superior Essex Cable 26 AWG 52 Pair Switchboard 100 Ohm 200A / 800A Series Cable 55-Y99-47
- Superior Essex Cable 26 AWG 25 Pair Switchboard 100 Ohm 200A / 800A Series Cable 55-N99-47
- Superior Essex Cable 26 AWG 103 Pair Switchboard 100 Ohm 200A / 800A Series Cable 55-E99-47
Product Details
The 200A and 800A Series Central Office (CO) Cables are designed for indoor use in central offices or in premises telephone rooms, and are utilized between a distribution frame and digital switching/transmission equipment. This series offers 24 and 26 AWG tinned copper at 100 Ohm characteristic impedance levels. Used primarily in Canada, the color code and lay-up scheme has distinctively colored insulation in combination with single dots and double dots or dashes of colored ink. Each wire within a unit is readily distinguishable from all other wires within the same unit. Cables may contain pairs or a combination of pairs and singles. The pairs and singles are assembled together to form a core. Some cable sizes contain āspare pairs.ā The core is covered by a gray PVC jacket. The 200A and 800A series meet or exceed all applicable requirements of TelcordiaĀ® GR-137.
Features:
ā¢ 24 and 26 AWG tinnedĀ copper conductors
ā¢ Solid PVC insulation
ā¢ 100 Ohm nominal impedance
ā¢ Standard pair lays
ā¢ CMR listed
ā¢ Non-shielded design
ā¢ Rip cord
Benefits:
ā¢ Small diameter and light weightresult in smaller cable bundlesand easier handling; tinned copperconductors minimize changein wire-wrap joint resistance
ā¢ Greater crush resistanceand improved transmission characteristics
ā¢ Impedance mismatch withOSP cable is minimized
ā¢ Improved crosstalk performanceand pair identification
ā¢ Suitable for horizontaland riser installations
ā¢ Lower cost
ā¢ Added ease of jacket removal
Specifications:
Conductor:
Tinned copper
Insulation:
PVC
Jacket:
Gray PVC
Jacket Marking:
Printed at 2 foot intervals on theĀ jacket; information includes productĀ identification, pair count, ULĀ information and sequential lengths inĀ feet and meters
Performance Compliance:
ā¢ TelcordiaĀ® GR-137-CORE, Issue 2, MayĀ 2013 (select sections)
ā¢ ASTM B33 - Tinned Copper
ā¢ ULĀ® 444
ā¢ CSA C22.2 No. 214-08
ā¢ UL 1666
ā¢ RoHS-compliant/RoHS 2-compliant
NRTL Programs:
UL, c(UL) Listed CMR
Applications:
ā¢ T1/DS1
ā¢ T1C/DS1C
technical specification | |
awg | 26 |
pair count | 132 |
nominal diameter in (mm) | 0.51 (13) |
approx. weight lbs/kft (kg/km) | 330 (491) |
standard length ft (m) | 700 (215) |
package | reel |
product code | 810A |
superior essex cable part number | 55-H99-47 |