Prysmian and Draka Cable 62 to 72 Fiber Count Plenum Dielectric CampusLink LT Dry Loose Tube Indoor Outdoor Cable
Select gauge from drop-down menu for prices:
- Prysmian and Draka Cable CampusLink LT Dry Loose Tube Indoor Outdoor Riser and Plenum Cable
- Prysmian and Draka Cable 2 to 60 Fiber Count Single Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 62 to 72 Fiber Count Single Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 74 to 84 Fiber Count Single Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 86 to 96 Fiber Count Single Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 98 to 108 Fiber Count Single Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 110 to 120 Fiber Count Single Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 122 to 132 Fiber Count Single Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 134 to 144 Fiber Count Single Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 146 to 216 Fiber Count Single Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 218 to 264 Fiber Count Single Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 266 to 288 Fiber Count Single Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 2 to 60 Fiber Count Double Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 62 to 72 Fiber Count Double Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 74 to 84 Fiber Count Double Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 86 to 96 Fiber Count Double Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 98 to 108 Fiber Count Double Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 110 to 120 Fiber Count Double Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 122 to 132 Fiber Count Double Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 134 to 144 Fiber Count Double Jacket CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 2 to 60 Fiber Count Corrugated Armor CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 62 to 72 Fiber Count Corrugated Armor CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 74 to 84 Fiber Count Corrugated Armor CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 86 to 96 Fiber Count Corrugated Armor CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 98 to 108 Fiber Count Corrugated Armor CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 110 to 120 Fiber Count Corrugated Armor CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 122 to 132 Fiber Count Corrugated Armor CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 134 to 144 Fiber Count Corrugated Armor CampusLink LT Dry Loose Tube Indoor Outdoor Riser Cable
- Prysmian and Draka Cable 2 to 60 Fiber Count Plenum Dielectric CampusLink LT Dry Loose Tube Indoor Outdoor Cable
- Prysmian and Draka Cable 74 to 84 Fiber Count Plenum Dielectric CampusLink LT Dry Loose Tube Indoor Outdoor Cable
- Prysmian and Draka Cable 86 to 96 Fiber Count Plenum Dielectric CampusLink LT Dry Loose Tube Indoor Outdoor Cable
- Prysmian and Draka Cable 98 to 144 Fiber Count Plenum Dielectric CampusLink LT Dry Loose Tube Indoor Outdoor Cable
Prysmian’s indoor-outdoor dry loose tube riser or plenum designs provide flame-rated network solutions for a diverse number of network applications. These cables combine flexible dry buffer tubes and swellable water blocking materials with Prysmian’s extensive portfolio of single-mode and multimode optical fibers. Incorporating proven outside plant design elements, this cable may be employed in outdoor aerial lashed, duct, and direct buried environments. Because of its application diversity, this advanced product eliminates the necessity and expense for traditional cable transition points once required in legacy systems. Cost savings and system long term reliability are achieved by enabling cable placement virtually anywhere in the network.
Applications: Multi-purpose indoor/outdoor aerial, lashed, duct, and direct buried
Constructions: Dielectric (single & dual jacket), ezPREP® corrugated armor, interlock armor
Flame Ratings: Riser (OFNR / OFCR / FT4) / Plenum (OFNP/OFCP/FT6)
Fiber Count: 2 to 288 (Riser) / 2-144 (Plenum)
Fiber Types: Single-mode (ESMF, bend-insensitive) multimode (62.5/125-OM1, 50/125-OM2+, OM3 & OM4)
Standards: TIA/EIA-568, ANSI/ICEA S-83-596, ANSI/ ICEA S-104-696, UL-1666, NFPA 262, CSA 22.2 No 230, Telcordia GR-409, Telcordia GR-20, CE RoHS Compliant
Registered Supplier: ISO 9001, ISO 14001, TL 9000, and OHSAS 18001
Features and Benefits:
• Fiber identification using TIA standardized color
coding
• Dry buffer tubes simplifies access and reduces
prep time
• Flame-retardant, black UV-resistant outer jacket
• Flexible kink-resistant buffer tubes for routing
and storage
• Available with bend-insensitive single-mode and
multimode optical fibers
• Interlock armor designs available for added
durability
• Will support all high performance networks including
OM4/10 gigabit ethernet systems
Technical Specification | |
Fiber Count | 62 to 72 |
# Buffer Tubes Outer/Inner Layer | 6 |
Fibers per Unit or # of Units | 12 |
Diameter Inches (mm) | 0.40 (10.2) |
Cable Weight lb/kft (kg/km) | 67 (99) |
Bend Radius Load Inches (cm) | 8.0 (20.4) |
Bend Radius No Load Inches (cm) | 4.0 (10.2) |