Superior Essex Cable 6 Fiber Count EnduraLite Indoor Outdoor Loose Tube OFNR Cable F360-006UXX-EYY1

Superior Essex Cable 6 Fiber Count EnduraLite Indoor Outdoor Loose Tube OFNR Cable F360-006UXX-EYY1

Product Details

EnduraLite® Dry Block, Sunlight Resistant Indoor/Outdoor Loose Tube riser and plenum rated cable lines offer the system designer the smallest form factor in a premises indoor/outdoor optical fiber cable. The cables can be installed in open spaces, trays, conduits, inner-ducts, trenches, steam tunnels and building riser or plenum locations. The cables incorporate the latest in dry water-blocking technology which eliminates the need to clean off the traditional gel-based water-blocking compounds. In the single unit design, a 3 mm central tube contains 2–to 12, 250 μm fibers and water blocking aramid yarns. In the multi-unit design, the water blocked 3mm subunits are stranded around a central strength element. The tube or core is surrounded by additional water blocking glass strength elements and an outer jacket, comprised of a rugged UL Listed, sunlight resistant, black polymer that allows for the cable to be exposed to long-term direct sunlight without the concern of material degradation. All fiber types are available, including 50/125 μm, 62.5/125 μm and single mode.

Features :
• Exceeds ANSI/TIA-568-C.3 optical performance
• Dry-block design meets Telcordia ANSI/ICEA S-104-696 water-block requirements
• 3 mm subunit
• UL/NEC Listed OFNR/OFNP
• All dielectric
• Jacket rip cord
• Black, UL Listed sunlight resistant outer jacket
• BrakeBox® payout control system
• Tube color indicates fiber type

Benefits :
• Future-proof fiber performance for current and future multigigabit applications
• Cable integrity maintained even if damage occurs to protective layers
• Attaches directly to MTP® or MPO mechanical connectors
• Eliminates the need to purchase separate cables for OSP and indoor/riser or plenum applications
• No additional grounding materials need to be purchased
• Saves time in cable preparation
• Long periods of direct sunlight exposure will not damage cable
• Adjustable tension control on reel prevents over spin and entangling of cable
• Quickly identifies the fiber type without searching for the jacket print

Specifications :

2 – 12 Fiber Single Unit Configuration
• 3 mm central subunit surrounded by additional water-blocking glass yarns and an outer jacket

24-48 Fiber Multi-Unit Configuration
• 3mm subunits stranded around a central strength element and surrounded by water blocking glass yarns, a ripcord and an outer jacket

Subunit Configuration
• 3mm subunits containing 2 to 12, 250 μm fibers and water blocking aramid yarns surrounded by a flame retardant PVC jacket

Subunit Strength Elements
• Water-blocking aramid yarns

Subunit Jacket
• Flame retardant (FR) PVC

Strength Elements
• Water-blocking glass yarns and/or glass reinforced plastic rod

Outer Jacket
• Riser: Black, FR, chemical and sunlight resistant PVC
• Plenum: Black, FR, chemical and sunlight resistant fluoropolymer

Performance Compliance
• UL 1651
• CSA C22.2 No. 232
• UL 1666
• NFPA 130 (Plenum)
• NFPA 262
• ANSI/ICEA S-83-596
• ANSI/ICEA S-104-696
• ANSI/TIA-568-C.3
• RoHS-compliant

NRTL Programs
• UL, c(UL) Listed OFNR/OFNP
• UL, c(UL) Listed Sunlight Resistant

Applications:
• Intra/inter-building backbones, such as conduit pathways or tunnels
• Conduit/duct/tray pathways
• Dry or wet locations

technical specification:
fiber count 6
listing OFNR
nominal diameter in (mm) 0.24 (6.1)
nominal weight lbs/kft (kg/km) 23 (34)
maximum tensile loading(install lbs (n)) 300 (1,340)
maximum tensile loading(long term lbs (n)) 90 (400)
minimum bend radius(install in (mm)) 3.6 (88)
minimum bend radius(long term in (mm)) 2.4 (60)
package¹ use key
Superior Essex Cable part number¹ F360-006UXX-EYY1