Superior Essex Cable 22 AWG 900 Pair Count SEALPIC–F RDUP PE-39 Solid Annealed Copper Cable 04-083-21

Superior Essex Cable 22 AWG 900 Pair Count SEALPIC–F RDUP PE-39 Solid Annealed Copper Cable 04-083-21

Select gauge from drop-down menu for prices:

Superior Essex Cable 22 AWG 900 Pair Count SEALPIC–F RDUP PE-39 Solid Annealed Copper Cable 04-083-21
Superior Essex Cable 22 AWG 900 Pair Count SEALPIC–F RDUP PE-39 Solid Annealed Copper Cable 04-083-21

SEALPIC®-F Cables are designed for low risk direct burial or duct applications. SEALPIC-F may be used aerially, but must be attached to a support strand.

Features:
• Twisted into pairs with varying lay lengths
• Core wrap
• Filled core
• Fully flooded shield interfaces
• Black, polyethylene jacket

Benefits:
• Minimizes crosstalk
• Provides thermal protection
• Moisture resistant
• Inhibits corrosion and water migration
• Provides a tough, protective covering designed to withstand exposure to direct sunlight, atmospheric temperature changes and stresses expected in standard installations

Specifications:
Conductor: Solid annealed copper

Insulation: Solid polyolefin; color coded in accordance with industry standards

Twisted Pairs: Individual insulated conductors; twisted into pairs with varying lay lengths; specific color combinations provide pair identification

≤ 25-Pair Core: Pairs are assembled into a cylindrical core

> 25-Pair Core: Cables larger than 25-pair are assembled into units, which are then used to assemble the core; units are identifiable using color-coded binders

Filling Compound: 80°C ETPR compound, completely filling the interstices between the pairs and under the core wrap

Core Wrap: Non-hygroscopic, dielectric tape applied over the core

Shield: Corrugated, copolymer coated, 8 mil aluminum tape applied longitudinally with an overlap; flooded shield interfaces

Jacket: Black, polyethylene

Jacket Marking: Identifying information includes a telephone handset, cable code, pair count, AWG, date of manufacture and sequential length markings at 2 foot intervals

Standards Compliance:
• ANSI/ICEA S-84-608-2011
• RDUP 7 CFR 1755.390 (PE-39)
• RoHS-compliant

Applications:
• Low risk direct burial
• Underground conduit
• Lashed aerial

technical specification:
awg (mm) 22 (0.64)
pair count 900
nominal diameter in (mm) 3.30 (84)
approx. weight lbs/kft (kg/km) 6,380 (9,495)
standard length ft (m) 1,250 (381)
approx. shipping weight lbs (kg) 7,975 (3,615)
reel size f x t x d (in) 96 x 40 x 48
superior essex cable part number 04-083-21

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question