Technical Data:
Halogen-free special data cable

Temperature Range:
• Flexing +5°C to +70°C
• Fixed installation -40°C to +70°C

Operating Peak Voltage:
• (Not for heavy current installation purposes)
• 0,14 mm² = 350 V
• ≥ 0,25 mm² = 500 V

Test Voltage:
• 0,14 mm² = 800 V
• ≥ 0,25 mm² = 1200 V

Insulation Resistance: Min. 2 GOhm x km

Capacitance: Core/core < 70 nF/km

Minimum Bending Radius:
• Flexing 7,5x cable Ø
• Fixed installation 4x cable Ø

Radiation Resistance: Up to 100x106 cJ/kg (up to 100 Mrad)

Cable Structure:
• Bare copper conductor, fine wire to DIN VDE 0812
• Conductor construction: 0,34 mm² = 7x0,25 mm
• Core insulation of PE compound type LD/MD to DIN VDE 0819-103 / DIN EN 50290-2-23
• Core identification to DIN 47100, without colour repetition
• Cores stranded in layers with optimal lay length
• Outer sheath compound type HM2 to DIN VDE 0207 part 24
• Sheath colour: grey (RAL 7005)
• With meter marking

Properties:
• PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values

Tests:
• Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)
• Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)
• Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)

Note:
• AWG sizes are approximate equivalent values. The actual cross section is in mm².
• Screened analogue type: DATAFLAMM®-C

Application:
DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.

technical specification
awg 20
no.cores x cross-sec. mm² 3 x 0,5
outer ø app. mm 4,9
cop. weight kg / km 14,2
weight app. kg / km 36,0
helukabel part number 52342