Helukabel 18 AWG 12 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13031

Helukabel 18 AWG 12 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13031

Select gauge from drop-down menu for prices:

Helukabel 18 AWG 12 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13031

Product Details

Technical Data:
• Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 / DIN EN 50525-2-51 and IEC 60227/75

Temperature Range:
• flexing -5°C to +70°C
• fixed installation -40°C to +70°C

Nominal Voltage: U0/U 300/500 V

Test Voltage: 2 kV, 5 minutes

Breakdown Voltage: min. 4000 V

Insulation Resistance:
• min. 20 MOhm x km

Minimum Bending Radius:
• flexing 7,5x cable Ø
• fixed installation 4x cable Ø

Radiation Resistance:
• up to 80x106 cJ/kg (up to 80 Mrad)

Cable Structure:
• Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5
• Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 / DIN EN 50363-3
• Core identification to DIN VDE 0293 black cores with continuous white numbering
• GN-YE conductor, 3 cores and above in the outer layer
• Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1/DIN EN 50363-4-1
• Sheath colour grey (RAL 7001)
• With meter marking

Properties:
• The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers

Tests:
• PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
• Oil resistant to DIN EN 60811-404

Note:
• G = with green-yellow conductor x = without green-yellow conductor (OZ)
• AWG sizes are approximate equivalent values. The actual cross-section is in mm².
• Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)

Application:
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.
These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.
These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

technical specification:
awg-no. 18
no.cores x cross-sec. mm² 12 G 1
outer ø min. - max. (mm) 11,8 - 14.6
cop. weight - kg/km 115,0
weight app. - kg/km 269,0
helukabel part number 13031

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question