Helukabel 14 AWG 3 Cores Megaflex 500 Halogen Free Flame Retardant Oil and UV Resistant Flexible Meter Marking Cable 13434

Helukabel 14 AWG 3 Cores Megaflex 500 Halogen Free Flame Retardant Oil and UV Resistant Flexible Meter Marking Cable 13434

Select gauge from drop-down menu for prices:

Helukabel 14 AWG 3 Cores Megaflex 500 Halogen Free Flame Retardant Oil and UV Resistant Flexible Meter Marking Cable 13434
Helukabel 14 AWG 3 Cores Megaflex 500 Halogen Free Flame Retardant Oil and UV Resistant Flexible Meter Marking Cable 13434

Technical Data:
• Halogen-free flexible control cable adapted to DIN VDE 0285-525-3-11 / DIN EN 50525-3-11, to UL Style 20939, UL Std.758.

Temperature Range
• flexing -30°C to +80°C
• fixed installation -40°C to +80°C

Nominal Voltage
• U0/U 300/500 V
• UL/CSA 600 V

Test Voltage
• 3000 V

Minimum Bending Radius
• flexing 10x cable Ø
• fixed installation 4x cable Ø

Flexibility
• Alternate bending test acc. to DIN VDE 0473-396 / DIN EN 50396

Cable Structure:
• Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5
• Core insulation of halogen-free special polymer
• Core identification to DIN VDE 0293 black cores with continuous white numbering
• GN-YE conductor, 3 cores and above in the outer layer
• Cores stranded in layers with optimal lay length
• Outer sheath of halogen-free special polymer
• Sheath colour: grey (RAL 7001) With meter marking
• LS0H= Low Smoke Zero Halogen

Properties:
• Highly flame retardant
• Resistant to oils and greases
• Resistant to UV and weathering
• Hydrolysis resistant
• Flexible, abrasion- and wear-resistant
• Ozone-resistant, recycleable
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers

Note:
• G = with GN-YE conductor x = without GN-YE conductor (OZ)
• Also available as a 0,6/1 kV cable Megaflex® 600
• AWG sizes are approximate equivalent values. The actual cross section is in mm².
• Screened analogue type: Megaflex® 500-C

Application:
• For fixed installation or flexible application, with free movements without forcing which do not constantly recur and without tensile stress, for high mechanical strain. As a measuring and control cable primarily in machinery and plant construction, in air-conditoning systems, at the warehouse and conveyor systems, in ship-building and in the renewable energies such as in the construction of wind power stations.

technical specification:
awg-no. 14
no.cores x cross-sec.mm² 3 G 2,5
outer ø app. mm 8,3
cop. weight kg/km 72,0
weight app. kg/km 151,0
helukabel part number 13434