Helukabel 20 AWG 30 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83312

Helukabel 20 AWG 30 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83312

Select gauge from drop-down menu for prices:

Helukabel 20 AWG 30 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83312
Helukabel 20 AWG 30 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83312

Technical Data:
• Special PVC command cable, approved to UL Style 2464, cores for AWG 26-20 to UL Style 1061/1729, for AWG 18-16 to UL Style 1007/1569

Temperature Range:
• flexing -10°C to +80°C
• fixed installation -20°C to +80°C

Nominal Voltage:
• 300 V

Test Voltage:
• 1500 V

Breakdown Voltage:
• min. 3000 V

Minimum Bending Radius:
• flexing 15x cable Ø
• fixed installation 7,5x cable Ø

Coupling Resistance:
• max. 250 Ohm/km

Cable Structure:
• Tinned copper conductor, fine wire, AWG 26-20 to ASTM-B 174-95 class J-M, AWG 18-16 to ASTM-B 286 Conductor make-up to: 0,14 mm² = 7x0,162 mm, 0,23 mm² = 7x0,202 mm, 0,34 mm² = 7x0,254 mm, 0,56 mm² = 7x0,32 mm, 0,82 mm² = 19x0,235 mm, 1,30 mm² = 19x0,31 mm
• Core insulation of special PVC class 43 respectively semirigid acc. to UL Std. 1581 tab.50.182 and 50.183
• Colour coded to DIN 47100 or international colour code
• Cores stranded in layers with optimal lay length
• Seperator-foil
• Drain wire
• Tinned copper wire braiding, approx. 85% coverage
• Outer sheath of PVC class 43 acc. to UL Std.1581 tab.50.182
• Sheath colour: black (international colour code), grey (DIN 47100 - preferred type)

Properties:
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers

To a Large Extent Resistant to:
• Oil
• Solvents
• Acids
• Lyes

Tests:
• PVC flame retardant acc. to UL VW-1, CSA FT1

Note:
• AWG sizes are approximate equivalent values. The actual cross section is in mm².
• Unscreened analogue types: command cable UL (LiYY)

Application:
• As a flexible interconnecting cable for electronics, control and command technology, as well as in measurement, signal, and pulse technology. Fast and inexpensive contacting by cutting and clamping technology.
• EMC = Electromagnetic compatibility
• To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
• = Product conforms with Low-Voltage Directive 2014/35/EU.

technical specification:
awg-no. 20
no.cores x cross-sec. mm² 30 X 0,56
sheath colour grey
outer ø app. - mm 12,4
cop. weight - kg/km 297,0
weight app. - kg/km 397,0
helukabel part number 83312

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question