Helukabel 22 AWG 4 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83288
Select gauge from drop-down menu for prices:
- Helukabel Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable
- Helukabel 26 AWG 2 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83254
- Helukabel 26 AWG 3 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83255
- Helukabel 26 AWG 4 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83256
- Helukabel 26 AWG 6 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83257
- Helukabel 26 AWG 10 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83258
- Helukabel 26 AWG 12 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83259
- Helukabel 26 AWG 16 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83260
- Helukabel 26 AWG 18 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83261
- Helukabel 26 AWG 24 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83262
- Helukabel 26 AWG 27 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83263
- Helukabel 26 AWG 30 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83264
- Helukabel 24 AWG 2 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83270
- Helukabel 24 AWG 3 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83271
- Helukabel 24 AWG 4 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83272
- Helukabel 24 AWG 6 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83273
- Helukabel 24 AWG 10 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83274
- Helukabel 24 AWG 12 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83275
- Helukabel 24 AWG 16 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83276
- Helukabel 24 AWG 18 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83277
- Helukabel 24 AWG 24 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83278
- Helukabel 24 AWG 27 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83279
- Helukabel 24 AWG 30 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83280
- Helukabel 22 AWG 2 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83286
- Helukabel 22 AWG 3 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83287
- Helukabel 22 AWG 6 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83289
- Helukabel 22 AWG 10 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83290
- Helukabel 22 AWG 12 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83291
- Helukabel 22 AWG 16 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83292
- Helukabel 22 AWG 18 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83293
- Helukabel 22 AWG 24 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83294
- Helukabel 22 AWG 27 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83295
- Helukabel 22 AWG 30 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83296
- Helukabel 20 AWG 2 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83302
- Helukabel 20 AWG 3 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83303
- Helukabel 20 AWG 4 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83304
- Helukabel 20 AWG 6 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83305
- Helukabel 20 AWG 10 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83306
- Helukabel 20 AWG 12 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83307
- Helukabel 20 AWG 16 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83308
- Helukabel 20 AWG 18 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83309
- Helukabel 20 AWG 24 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83310
- Helukabel 20 AWG 27 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83311
- Helukabel 20 AWG 30 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83312
- Helukabel 18 AWG 2 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83318
- Helukabel 18 AWG 3 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83319
- Helukabel 18 AWG 4 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83320
- Helukabel 18 AWG 6 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83321
- Helukabel 18 AWG 10 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83322
- Helukabel 18 AWG 12 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83323
- Helukabel 18 AWG 16 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83324
- Helukabel 18 AWG 18 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83325
- Helukabel 18 AWG 24 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83326
- Helukabel 18 AWG 27 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83327
- Helukabel 18 AWG 30 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83328
- Helukabel 16 AWG 2 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83334
- Helukabel 16 AWG 3 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83335
- Helukabel 16 AWG 4 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83336
- Helukabel 16 AWG 6 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83337
- Helukabel 16 AWG 10 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83338
- Helukabel 16 AWG 12 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83339
- Helukabel 16 AWG 16 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83340
- Helukabel 16 AWG 18 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83341
- Helukabel 16 AWG 24 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83342
- Helukabel 16 AWG 27 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83343
- Helukabel 16 AWG 30 Cores Grey Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83344
- Helukabel 26 AWG 2 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83976
- Helukabel 26 AWG 3 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83977
- Helukabel 26 AWG 4 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83978
- Helukabel 26 AWG 6 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83979
- Helukabel 26 AWG 10 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83980
- Helukabel 26 AWG 12 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83981
- Helukabel 26 AWG 16 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83982
- Helukabel 26 AWG 18 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83983
- Helukabel 26 AWG 24 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83984
- Helukabel 26 AWG 27 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83985
- Helukabel 26 AWG 30 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83986
- Helukabel 24 AWG 2 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83987
- Helukabel 24 AWG 3 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83988
- Helukabel 24 AWG 4 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83989
- Helukabel 24 AWG 6 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83990
- Helukabel 24 AWG 10 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83991
- Helukabel 24 AWG 12 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83992
- Helukabel 24 AWG 16 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83993
- Helukabel 24 AWG 18 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83994
- Helukabel 24 AWG 24 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83995
- Helukabel 24 AWG 27 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83996
- Helukabel 24 AWG 30 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 83997
- Helukabel 22 AWG 2 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65044
- Helukabel 22 AWG 3 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65045
- Helukabel 22 AWG 4 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65046
- Helukabel 22 AWG 6 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65047
- Helukabel 22 AWG 10 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65048
- Helukabel 22 AWG 12 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65049
- Helukabel 22 AWG 16 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65050
- Helukabel 22 AWG 18 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65051
- Helukabel 22 AWG 24 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65052
- Helukabel 22 AWG 27 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65053
- Helukabel 22 AWG 30 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65054
- Helukabel 20 AWG 2 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65055
- Helukabel 20 AWG 3 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65056
- Helukabel 20 AWG 4 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65057
- Helukabel 20 AWG 6 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65058
- Helukabel 20 AWG 10 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65059
- Helukabel 20 AWG 12 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65060
- Helukabel 20 AWG 16 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65061
- Helukabel 20 AWG 18 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65062
- Helukabel 20 AWG 24 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65063
- Helukabel 20 AWG 27 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65064
- Helukabel 20 AWG 30 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65065
- Helukabel 18 AWG 2 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65066
- Helukabel 18 AWG 3 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65067
- Helukabel 18 AWG 4 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65068
- Helukabel 18 AWG 6 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65069
- Helukabel 18 AWG 10 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65070
- Helukabel 18 AWG 12 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65071
- Helukabel 18 AWG 16 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65072
- Helukabel 18 AWG 18 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65073
- Helukabel 18 AWG 24 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65074
- Helukabel 18 AWG 27 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65075
- Helukabel 18 AWG 30 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65076
- Helukabel 16 AWG 2 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65077
- Helukabel 16 AWG 3 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65078
- Helukabel 16 AWG 4 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65079
- Helukabel 16 AWG 6 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65080
- Helukabel 16 AWG 10 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65081
- Helukabel 16 AWG 12 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65082
- Helukabel 16 AWG 16 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65083
- Helukabel 16 AWG 18 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65084
- Helukabel 16 AWG 24 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65085
- Helukabel 16 AWG 27 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65086
- Helukabel 16 AWG 30 Cores Black Sheath Colour Command Cable UL LiYCY Style 2464 300V 80°C EMC-Preferred Type Tinned Copper Cable 65087
Technical Data:
• Special PVC command cable, approved to UL Style 2464, cores for AWG 26-20 to UL Style 1061/1729, for AWG 18-16 to UL Style 1007/1569
Temperature Range:
• flexing -10°C to +80°C
• fixed installation -20°C to +80°C
Nominal Voltage:
• 300 V
Test Voltage:
• 1500 V
Breakdown Voltage:
• min. 3000 V
Minimum Bending Radius:
• flexing 15x cable Ø
• fixed installation 7,5x cable Ø
Coupling Resistance:
• max. 250 Ohm/km
Cable Structure:
• Tinned copper conductor, fine wire, AWG 26-20 to ASTM-B 174-95 class J-M, AWG 18-16 to ASTM-B 286 Conductor make-up to: 0,14 mm² = 7x0,162 mm, 0,23 mm² = 7x0,202 mm, 0,34 mm² = 7x0,254 mm, 0,56 mm² = 7x0,32 mm, 0,82 mm² = 19x0,235 mm, 1,30 mm² = 19x0,31 mm
• Core insulation of special PVC class 43 respectively semirigid acc. to UL Std. 1581 tab.50.182 and 50.183
• Colour coded to DIN 47100 or international colour code
• Cores stranded in layers with optimal lay length
• Seperator-foil
• Drain wire
• Tinned copper wire braiding, approx. 85% coverage
• Outer sheath of PVC class 43 acc. to UL Std.1581 tab.50.182
• Sheath colour: black (international colour code), grey (DIN 47100 - preferred type)
Properties:
• The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
To a Large Extent Resistant to:
• Oil
• Solvents
• Acids
• Lyes
Tests:
• PVC flame retardant acc. to UL VW-1, CSA FT1
Note:
• AWG sizes are approximate equivalent values. The actual cross section is in mm².
• Unscreened analogue types: command cable UL (LiYY)
Application:
• As a flexible interconnecting cable for electronics, control and command technology, as well as in measurement, signal, and pulse technology. Fast and inexpensive contacting by cutting and clamping technology.
• EMC = Electromagnetic compatibility
• To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
• = Product conforms with Low-Voltage Directive 2014/35/EU.
technical specification: | |
awg-no. | 22 |
no.cores x cross-sec. mm² | 4 X 0,34 |
sheath colour | grey |
outer ø app. - mm | 5,1 |
cop. weight - kg/km | 28,7 |
weight app. - kg/km | 60,0 |
helukabel part number | 83288 |