General Cable CHTC® XLPE XL-CPE Type TC 18 AWG 24 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
Select gauge from drop-down menu for prices:
- General Cable CHTC® XLPE XL-CPE Type TC Individual and Overall Shielded Pairs Triads Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 18 AWG 1 Pair Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 18 AWG 1 Triad Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 18 AWG 2 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 18 AWG 4 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 18 AWG 8 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 18 AWG 12 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 18 AWG 16 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 18 AWG 20 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 18 AWG 36 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 18 AWG 50 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 16 AWG 1 Pair Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 16 AWG 1 Triad Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 16 AWG 2 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 16 AWG 4 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 16 AWG 8 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 16 AWG 12 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 16 AWG 16 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 16 AWG 20 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 16 AWG 24 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 16 AWG 36 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
- General Cable CHTC® XLPE XL-CPE Type TC 16 AWG 50 Pairs Individual and Overall Shielded Instrumentation Shielded 600V UL
Conductor:
• 18 AWG and 16 AWG tinned, annealed copper per ASTM B33
• Class B stranding per ASTM B8
Insulation:
• Flame-retardant Cross-linked Polyethylene (XLPE)
• Color-coded per ICEA Method 1: Pairs - black and white; Triads - black, white and red. One conductor in each pair or triad is printed alphanumerically for easy identification
Shield:
Individual and overall shielded pairs/triads
• Individual pairs/triads are 100% shielded with Flexfoil® aluminum/polyester in contact with stranded tinned copper drain wire
• Overall shield is Flexfoil® aluminum/polymer in contact with stranded tinned copper drain wire
Jacket: Lead-free Cross-linked Chlorinated Polyethylene (XL-CPE)
Applications:
• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial hazardous locations per NEC
Features:
• Rated at 90?C wet or dry
• Ripcord applied to all cables with jacket thickness of 60 mils or less
• Oil-resistant jacket
• Sunlight- and weather-resistant
• Excellent electrical, thermal and physical properties
• Excellent moisture resistance
• Excellent flame resistance
• “Heavy duty” rating per ICEA standards
• Excellent low temperature cold bend characteristics
• Meets cold bend test at -40?C
Compliances:
Industry Compliances:
• UL 1277 Type TC, UL File # E57179
• UL 1581
• ICEA S-73-532/WC57
• RoHS Compliant
Flame Test Compliances:
• UL 1581/UL 2556 VW-1
• UL 1685 Vertical Flame Test
• IEEE 383
• IEEE 1202
• CSA FT4
• ICEA T-29-520
Other Compliances:
• EPA 40 CFR, Part 261 for leachable lead content per TCLP
• OSHA Acceptable
Packaging: Material cut to length and shipped on non-returnable wood reels
technical specification: | |
cond. size (awg) | 18 |
no. of pairs/ triads | 24 |
cond. strand | 7W |
minimum avg. insulation thickness(inches) | 0.030 |
minimum avg. insulation thickness(mm) | 0.76 |
minimum avg. jacket thickness(inches) | 0.080 |
minimum avg. jacket thickness(mm) | 2.03 |
nominal cable o.d.(inches) | 1.450 |
nominal cable o.d.(mm) | 36.83 |
copper weight(lbs/ 1000 ft kg) | 308 |
copper weight(kg/km) | 459 |
net weight(lbs/ 1000 ft kg) | 795 |
net weight(kg/km) | 1183 |
catalog number | 337690* |