General Cable FREP® FR-EPR CPE Type TC 18/2 Gauge Individual and Overall Shielded Pairs Instrumentation Shielded 600V UL

General Cable FREP® FR-EPR CPE Type TC 18/2 Gauge Individual and Overall Shielded Pairs Instrumentation Shielded 600V UL

Select gauge from drop-down menu for prices:

General Cable FREP® FR-EPR CPE Type TC 18/2 Gauge Individual and Overall Shielded Pairs Instrumentation Shielded 600V UL
FREP FR-EPR CPE Type TC 18/2 Gauge Individual and Overall Shielded Pairs Instrumentation Shielded 600V UL

Conductor:
• 18 AWG and 16 AWG tinned, annealed copper per ASTM B33
• Class B stranding per ASTM B8

Insulation:
• Flame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
• Color-coded per ICEA Method 1: Pairs - black and white. One conductor in each pair is printed alphanumerically for easy identification

Shield:
Individual and overall shielded pairs:
• Individual pairs are 100% individually shielded with Flexfoil® aluminum/polyester in contact with stranded tinned copper drain wire
• Overall shield is Flexfoil® aluminum/polymer in contact with stranded tinned copper drain wire

Jacket: Lead-free, flame-retardant, thermoplastic Chlorinated Polyethylene (CPE)

Applications:
• In free air, raceways or direct burial
• In wet or dry locations
• Permitted for use in Class I, Division 2 industrial hazardous locations per NEC

Features:
• Rated at 90?C wet or dry
• Ripcord applied to all cables with jacket thickness of 60 mils or less
• Excellent physical, thermal and electrical properties
• Excellent moisture resistance
• Excellent resistance to compression cuts and heat deformation
• Excellent flame resistance—burns to an ash; does not exhibit thermoplastic drip
• Low coefficient of friction for easy pulling
• Sunlight- and weather-resistant
• Excellent low temperature cold bend characteristics
• Meets cold bend test at -40?C

Compliances:
Industry Compliances:
• UL 1277 Type TC, UL File # E57179
• UL 1581
• ICEA S-73-532/NEMA WC57
• RoHS Compliant

Flame Test Compliances:
• UL 1581/UL 2556 VW-1
• UL 1685 Vertical Flame Test
• IEEE 383
• IEEE 1202
• CSA FT4
• ICEA T-29-520

Other Compliances:
• EPA 40 CFR, Part 261 for leachable lead content per TCLP
• OSHA Acceptable

Packaging: Material cut to length and shipped on non-returnable wood reels

technical specification:
cond. size(awg) 18
no. of pairs 2
cond. strand 7W
minimum avg. insulation thickness(inches) 0.025
minimum avg. insulation thickness(mm) 0.64
minimum avg. jacket thickness(inches) 0.045
minimum avg. jacket thickness(mm) 1.14
nominal cable o.d.(inches) 0.473
nominal cable o.d.(mm) 12.01
copper weight(lbs/1000 ft) 27
copper weight(kg/km) 41
net weight(lbs/1000 ft) 83
net weight(kg/km) 124
catalog number 279700

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question