HW121 Instrumentation Cable 600 Volt Type TC-LS, 90°C Single & Multiple Triads Individual and Overall Shield XLP Insulation Low Smoke Zero Halogen Jacket Tinned Copper Conductors FM Approved - 16 AWG - 2 Triad
Select gauge from drop-down menu for prices:
- HW121 Instrumentation Cable 600 Volt Type TC-LS, 90°C Single & Multiple Triads Individual and Overall Shield XLP Insulation Low Smoke Zero Halogen Jacket Tinned Copper Conductors FM Approved
- HW121 Instrumentation Cable 600 Volt Type TC-LS, 90°C Single & Multiple Triads Individual and Overall Shield XLP Insulation Low Smoke Zero Halogen Jacket Tinned Copper Conductors FM Approved - 16 AWG - 1 Triad
- HW121 Instrumentation Cable 600 Volt Type TC-LS, 90°C Single & Multiple Triads Individual and Overall Shield XLP Insulation Low Smoke Zero Halogen Jacket Tinned Copper Conductors FM Approved - 16 AWG - 4 Triad
- HW121 Instrumentation Cable 600 Volt Type TC-LS, 90°C Single & Multiple Triads Individual and Overall Shield XLP Insulation Low Smoke Zero Halogen Jacket Tinned Copper Conductors FM Approved - 16 AWG - 6 Triad
Technical Specifications: | |
Catalog Number | HW121 01602 |
Size AWG | 16 |
No. of Pairs |
2 |
Insulation Thickness Mils | 30 |
Jacket Thickness Mils | 60 |
Overall Diameter Inch |
0.64 |
Net Weight Lbs/Mft | 170 |
Specifications:
- HW121
- Instrumentation Cable
- 600 Volt Type TC-LS, 90°C
- Single & Multiple Triads
- Individual and Overall Shield
- XLP Insulation
- Low Smoke Zero Halogen Jacket
- Tinned Copper Conductors
- FM Approved
Application:
LifeGuard™ Low Smoke Zero Halogen* cable is for use in instrumentation and process control applications where protection from electrostatic interference is required. It is highly flame-retardant, produces very small amounts of smoke when burned and contains no halogens. LifeGuard™ cable is ideal for applications where a high degree of safety and equipment protection is required.
LifeGuard™ cable is NEC listed as Type TC-LS and approved for installation indoors or outdoors, aerially, in conduits, ducts, cable trays and direct burial in circuits not exceeding 600 volts. It may be installed in temperatures as low as -30°C and used in NEC Class 1, Division 2 hazardous locations. It is NEC approved for continuous operation at 90°C in wet and dry locations, 130°C for emergency overload conditions, and 250°C for short circuit conditions.
Product Features:
- FM Approved per cable fire propagation Standard 2972, Group 1
- Tray rated
- Sunlight-resistant
- Approved for direct burial
- Tinned conductors provide ease of termination and added protection in caustic environments
- Superior electrostatic interference protection from individual and overall shield
- Very low smoke production when burned
- LifeGuard™ jacket produces zero halogens during fire - less toxic and corrosive
- LifeGuard™ jacket is environmentally safe - lead, sulfur and halogen free
- Highly chemical resistant
- Very flame retardant
- Burns to an ash - does not exhibit thermoplastic drip
- Excellent compression and impact resistance
- Superior tensile strength and abrasion resistance
- Flexible jacket with low coefficient of friction
Conductors:
7 strand tin coated, soft annealed copper per ASTM B-33, Class B stranding per ASTM B-8
Insulation:
Cross-linked polyethylene (XLP)per UL Standard 44
Individual Shield:
Aluminum-polymer tape providing 100% coverage with a flexible 7 strand tinned copper drain wire
Overall Shield:
Aluminum-polymer tape providing 100% coverage with a flexible 7 strand tinned copper drain wire
Jacket:
- Sunlight-resistant and flame-retardant, Low Smoke Zero Halogen polyolefin per UL Standard 1277
- A ripcord is applied longitudinally under the jacket to facilitate stripping
Flame Tests:
- FM Approved - Class 3972 Specification Test Standard - Cable Fire Propagation Group 1
- UL Standard 1581 70,000 BTU/hr flame test
- ICEA T-29-520 210,000 BTU/hr flame test
- Flame Test Listings May Vary By Cable Size
Color Code:
ICEA Method 1: black, white and red twisted triads with numbers
Additional Standards:
- NEC Type TC per articles 336, 392, and 501.4 (b) and Class 1 circuits per NEC article 725
- UL Standard 1685 70,000 BTU/hr Flame Propagation and Smoke Release Test