General Cable EmPowr® 500Kcmil 37 Wires 15 kV Concentric Neutral LLDPE Jacket Fill Underground Distribution Cable Al Cond. EPR Insulation TYPE UD 175 mils

General Cable EmPowr® 500Kcmil 37 Wires 15 kV Concentric Neutral LLDPE Jacket Fill Underground Distribution Cable Al Cond. EPR Insulation TYPE UD 175 mils

Select gauge from drop-down menu for prices:

General Cable EmPowr® 500Kcmil 37 Wires 15 kV Concentric Neutral LLDPE Jacket Fill Underground Distribution Cable Al Cond. EPR Insulation TYPE UD 175 mils
EmPowr 500Kcmil 37 Wires 15 kV Concentric Neutral LLDPE Jacket Fill Underground Distribution Cable Al Cond. EPR Insulation TYPE UD 175 mils

Complete Cable: Cross-linked semi-conducting conductor shield, insulation and semi-conducting insulation shield are extruded over a solid or stranded aluminum conductor and cured in a single operation. Uncoated copper neutral wires (helically applied) and extruded-to-fill black jacket are applied over the cable core. These products meet the latest requirements of ANSI/ICEA S-94-649, AEIC CS8 and RUS U1 as applicable for Ethylene Propylene Rubber (EPR) insulated concentric neutral cable. 

Conductor: Solid or Class B compressed concentric lay stranded 1350 aluminum. 

Conductor Shield: Extruded semi-conducting thermosetting polymeric stress control layer. 

Insulation: Extruded Ethylene Propylene Rubber (EPR) Class II and III. 

Insulation Shield: Extruded semi-conducting thermosetting layer, clean and free stripping from insulation. 

Concentric Neutral: Helically applied, annealed, solid bare copper wires. 

Jacket: Black, non-conducting, sunlight-resistant, Linear Low-Density Polyethylene (LLDPE) extruded to fill spaces between neutral wires. 

Features and Benefits: 
• Triple extruded for clean interfaces 
• Class 10,000 environment utilized for cable core material handling 
• Flexibility for easy handling 
• Excellent moisture resistance 
• Deformation-resistant 
• High dielectric strength 
• Low dielectric loss 
• Excellent resistance to water treeing 
• Clean-stripping insulation shield without the use of a release agent 
• Sunlight-resistant 

Temperature Rating: 
• Normal - 105°C 
• Emergency* - 140°C 
• Short Circuit - 250°C

Applications: EmPowr® Fill cables are intended for use in dry or wet locations for distribution of single or three phase medium-voltage power. Cables with a full neutral are designed for use on single phase underground distribution (UD) applications. Cables with a 1/3 neutral are designed for use in three phase UD applications. The full neutral cable is sometimes referred to as an underground residential distribution (URD) cable. These cables may be installed in ducts or direct buried. 

 

Options: 
• Copper conductors 
• EmPowr® Fill LF Lead-Free EAM 
• STRANDFILL® blocked conductor. Tested in accordance with ICEA T-31-610 
• BIFILL® blocked conductor and cable core/ jacket. Tested in accordance with ICEA T-34-664 
• Dry nitrogen cure 
• True Triple Extrusion 
• Flat strap concentric neutral 
• Red stripes on jacket 
• Semi-conducting thermoplastic jacket 
• Overlaying PVC jacket with separator tape 
• Deformation-resistant polypropylene jacket 
• CDC® Combined Duct & Cable 
• 3 X 1/C triplex or parallel 
• Type MV-90 UL 1072 
• Type MV-105 UL 1072 (PVC jacket only) 
• UL Listed 
• Alternative neutral configurations

technical specification:
compressed conductor(al awg or kcmil) 500
compressed conductor(no.of wires) 37
copper neutral(no.of wires) 25
copper neutral(wire size awg)
14
diameter (1)inches(insulation in min.) 1.150
diameter (1)inches(insulation in max.) 1.235
diameter (1)inches(encap lldpe jacket)
1.501
nominal jacket thkn.inches(1) 0.055
approx. weight (1)lb/1000 ft(al cond.) 468
approx. weight (1)lb/1000 ft(cu neut.wires) 334
approx. weight (1) lb/1000 ft(total) 1377
ampacity (2)(direct buried) 530
ampacity (2)(induct) 420

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question