General Cable HVTECK® 3C 1 AWG 175 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 15kV CSA
Select gauge from drop-down menu for prices:
- General Cable HVTECK® 3C 175 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 15kV CSA
- General Cable HVTECK® 3C 2 AWG 175 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 15kV CSA
- General Cable HVTECK® 3C 1/0 AWG 175 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 15kV CSA
- General Cable HVTECK® 3C 2/0 AWG 175 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 15kV CSA
- General Cable HVTECK® 3C 3/0 AWG 175 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 15kV CSA
- General Cable HVTECK® 3C 4/0 AWG 175 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 15kV CSA
- General Cable HVTECK® 3C 250MCM 175 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 15kV CSA
- General Cable HVTECK® 3C 350MCM 175 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 15kV CSA
- General Cable HVTECK® 3C 500MCM 175 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 15kV CSA
- General Cable HVTECK® 3C 750MCM 175 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 15kV CSA
- General Cable HVTECK® 3C 1000MCM 175 Mils TRXLPE Tape Shield PVC AIA PVC Power Shielded Armored 15kV CSA
Conductor: 2 AWG thru 1000 kcmil bare copper compact Class B strand
Strand Shield: A thermoset semi-conducting strand shield is extruded over the conductor
Insulation: Tree-Retardant Cross-linked Polyethylene (TRXLPE)
Insulation Shield:
• This consists of a semi-conducting thermosetting layer, applied in a triple extrusion process, plus a helically applied gapped copper tape
• Color-coded: black, red or blue colored tape placed longitudinally under the copper tape shield
Ground (Bonding) Conductor: The conductor consists of one uninsulated stranded bare copper conductor
Inner Jacket: Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black
Armor: Aluminum Interlocked Armor (AIA)
Overall Jacket: Lead-free, ACID-FLAME-CHECK ??® flameretardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), red
Options: Galvanized Steel Interlocked Armor (GSIA)
Applications:
• For wiring in all hazardous locations when used with certified HL cable glands
• For exposed and concealed wiring in dry, damp or wet locations
• For use in ventilated, non-ventilated and laddertype cable trays in dry, damp or wet locations
• For direct earth burial (with protection as required by inspection authority)
Features:
• Rated at 90?C wet or dry
• Excellent crush, oil and chemical resistance
• Provides long service life
• Cost-effective alternative to installations in conduit
• Meets cold bend and impact tests at -40?C
Compliances:
Industry Compliances:
• CSA Standard C22.2 No. 131 and No. 174
• CSA Standard C68.10
Flame Test Compliances:
• CSA FT1 and FT4
• IEEE 383 (70,000 BTU/hr)
• UL 1581 (70,000 BTU/hr)
• IEEE 1202 (70,000 BTU/hr) CSA FT4
• ICEA T-30-520 (70,000 BTU/hr)
• ICEA T-29-520 (210,000 BTU/hr)
Other Compliances:
• Hazardous Location Rating: HL
• EPA 40 CFR, Part 261 for leachable lead content per TCLP method
• OSHA Acceptable
• RoHS Compliant
Packaging:
• For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing
• For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing
technical specification: | |
cond.size(awg/kcmil) | 1 |
no.of cond.
|
3 |
ground wire size(awg)
|
6 |
nominal diameter (over)(insulation in inches) | 0.69 |
nominal diameter (over)(insulation in mm) | 17.5 |
nominal diameter (over)(insulation shield in inches) | 0.76 |
nominal diameter (over)(insulation shield in mm) | 19.3 |
nominal diameter (over)(inner jacket in inches) | 1.89 |
nominal diameter (over)(inner jacket in mm) | 48.0 |
nominal diameter (over)(armor in inches) | 2.18 |
nominal diameter (over)(armor in mm) | 55.4 |
nominal diameter (over)(cable in inches) | 2.27 |
nominal diameter (over)(cable in mm) | 57.7 |
copper weight(lbs/1000 ft) | 955 |
copper weight(kg/km) | 1421 |
net weightw/armor(lbs/1000 ft in al) | 2620 |
net weight w/armor (lbs/1000 ft in steel)
|
3490 |
net weightw/armor(kg/km in al) | 3890 |
net weightw/armor(kg/km in steel) | 5190 |
outdoor ampacity**(40?c ambient)
|
161 |
catalog number | 17496.830100* |