Prysmian and Draka Cable 1000 MCM Bostrail Traction Power Cable Single Conductor EPR Insulated XLPO Jacket 2000V TR1000
Select gauge from drop-down menu for prices:
- Prysmian and Draka Cable Bostrail Traction Power Cable Single Conductor EPR Insulated XLPO Jacket 4/0 AWG to 2000 MCM 2000V
- Prysmian and Draka Cable 4/0 AWG Bostrail Traction Power Cable Single Conductor EPR Insulated XLPO Jacket 2000V TR0000
- Prysmian and Draka Cable 500 MCM Bostrail Traction Power Cable Single Conductor EPR Insulated XLPO Jacket 2000V TR0500
- Prysmian and Draka Cable 750 MCM Bostrail Traction Power Cable Single Conductor EPR Insulated XLPO Jacket 2000V TR0750
- Prysmian and Draka Cable 1500 MCM Bostrail Traction Power Cable Single Conductor EPR Insulated XLPO Jacket 2000V TR1500
- Prysmian and Draka Cable 2000 MCM Bostrail Traction Power Cable Single Conductor EPR Insulated XLPO Jacket 2000V TR2000
Conductor: The conductor is class “B” stranded compressed concentric round in accordance with ASTM B8. The wires are uncoated soft, annealed copper of 100% conductivity in accordance with ASTM B3. The conductor resistance meets the requirements of ICEA S-95-658 (NEMA WC70).
Insulation: Low smoke non-halogen ethylene propylene rubber (EPR) rated for 90°C wet or dry, complying with ICEA standards (see chart on back). The insulation fits tightly to the conductor but is ‘clean-stripping.’ An opaque polyester tape or other suitable separator is used over the conductor.
Jacket: Flame retardant, low smoke non-halogen and oil resistant crosslinked polyolefin (XLPO) jacket (see chart on back). The jacket is bonded to the EPR insulation.
Applications: These are single conductor 2000 volt power cables where low-smoke non-halogen cables are required. They consist of a ethylene propylene rubber insulated conductor jacketed with a tough low smoke zero halogen (LSZH) crosslinked polyolefin (XLPO) jacket. They are highly heat, oil and moisture-resistant, extremely tough yet flexible, and can sustain 90°C wet or dry operating temperatures. A shielded version is available as well.
Ratings:
• Rated 90°C Wet or Dry Traction Power Cable
• UL 1581 Vertical Tray (70,000 BTU)
• UL RHW-2
technical specification: | |
conductor size | 1000 MCM |
stranding | 61/w |
average insulation thickness in (mm) | .125 (3.2) |
average jacket thickness in (mm) | .095 (2.4) |
minimum bend radius in (cm) | 6.5 (165) |
ampacity* 90°c | 1055 |
cable o.d in (mm) | 1.580 (40.1) |
approximate cable weight lbs/mft (kg/km) | 3710 (5528) |
prysmian and draka cable part number | TR1000 |