Prysmian and Draka Cable 400 MCM 3990/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F20400
Select gauge from drop-down menu for prices:
- Prysmian and Draka Cable Bostrail Fire Safe LSZH Single Conductor XLPO jacket 22 AWG to 500 MCM 600 and 2000 volt Cable
- Prysmian and Draka Cable 22 AWG 7/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 600 Volt Cable F60022
- Prysmian and Draka Cable 20 AWG 10/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 600 Volt Cable F60020
- Prysmian and Draka Cable 18 AWG 16/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 600 Volt Cable F60018
- Prysmian and Draka Cable 16 AWG 26/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 600 Volt Cable F60016
- Prysmian and Draka Cable 14 AWG 41/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 600 Volt Cable F60014
- Prysmian and Draka Cable 12 AWG 65/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 600 Volt Cable F60012
- Prysmian and Draka Cable 10 AWG 104/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 600 Volt Cable F60010
- Prysmian and Draka Cable 8 AWG 168/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 600 Volt Cable F60008
- Prysmian and Draka Cable 6 AWG 266/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 600 Volt Cable F60006
- Prysmian and Draka Cable 4 AWG 420/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 600 Volt Cable F60004
- Prysmian and Draka Cable 2 AWG 655/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 600 Volt Cable F60002
- Prysmian and Draka Cable 16 AWG 26/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F20016
- Prysmian and Draka Cable 14 AWG 41/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F20014
- Prysmian and Draka Cable 12 AWG 65/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F20012
- Prysmian and Draka Cable 10 AWG 104/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F20010
- Prysmian and Draka Cable 8 AWG 168/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F20008
- Prysmian and Draka Cable 6 AWG 266/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F20006
- Prysmian and Draka Cable 4 AWG 420/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F20004
- Prysmian and Draka Cable 2 AWG 655/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F20002
- Prysmian and Draka Cable 1 AWG 836/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F20001
- Prysmian and Draka Cable 1/0 AWG 1064/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F201/0
- Prysmian and Draka Cable 2/0 AWG 1323/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F202/0
- Prysmian and Draka Cable 3/0 AWG 1666/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F203/0
- Prysmian and Draka Cable 4/0 AWG 2107/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F204/0
- Prysmian and Draka Cable 250 MCM 2499/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F20250
- Prysmian and Draka Cable 300 MCM 2989/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F20300
- Prysmian and Draka Cable 350 MCM 3485/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F20350
- Prysmian and Draka Cable 450 MCM 4572/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F20450
- Prysmian and Draka Cable 500 MCM 5054/30 Stranding Bostrail Fire Safe LSZH Single Conductor XLPO jacket 2000 Volt Cable F20500
Conductor: The conductor is class “K” stranded in accordance with ASTM B172. The wires are soft, annealed copper with a continuous coating of tin (98.0% conductivity) in accordance with ASTM B33. The conductor resistance meets the requirements of ICEA S-95-658 (NEMA WC70).
Insulation: Low smoke silicone rubber to comply with appropriate specifications (see chart on back). The insulation fits the conductor tightly but is “clean stripping.” An opaque polyester tape or other suitable separator is used over the conductor.
Jacket: Flame retardant, low smoke non-halogen and oil resistant crosslinked polyolefin (XLPO) jacket (see chart on back). The jacket is bonded to the EPR insulation.
Applications: These are single conductor 600 and 2000 volt power cables designed for low-smoke environments such as tunnels and subway systems. They consist of silicone rubber insulated conductor jacketed with a tough low smoke zero halogen (LSZH) crosslinked polyolefin (XLPO) jacket. They are highly heat, oil and moisture-resistant, extremely tough yet Flexible, and can sustain 125°C operating temperatures.
Ratings:
• UL 1581 Flame Test
• IEEE 383 Paragraph 2.5
technical specification: | |
conductor size | 400 MCM |
stranding | 3990/30 |
voltage rating
|
2000 |
average insulation/jacket thickness in (mm) | .110 (2.8) |
bend radius in (mm) | 4.45 (113.0) |
ampacity* 90°c
|
615 |
ampacity* 125°c
|
742 |
cable o.d in (mm) | 1.110 (28.2) |
approximate cable weight lbs/mft (kg/km)
|
1545 (2302) |
Prysmian and draka cable part number | F20400 |