Amercable 4/0 AWG Red Jumper Cable Flexible 5000/15000 Volts 90C 37-221-040
Select gauge from drop-down menu for prices:
- Amercable Red Jumper Cable Flexible 5000/15000 Volts 90C 37-221
- Amercable 8 AWG Red Jumper Cable Flexible 5000/15000 Volts 90C 37-221-008
- Amercable 6 AWG Red Jumper Cable Flexible 5000/15000 Volts 90C 37-221-006
- Amercable 4 AWG Red Jumper Cable Flexible 5000/15000 Volts 90C 37-221-004
- Amercable 3 AWG Red Jumper Cable Flexible 5000/15000 Volts 90C 37-221-003
- Amercable 2 AWG Red Jumper Cable Flexible 5000/15000 Volts 90C 37-221-002
- Amercable 1 AWG Red Jumper Cable Flexible 5000/15000 Volts 90C 37-221-001
- Amercable 1/0 AWG Red Jumper Cable Flexible 5000/15000 Volts 90C 37-221-010
- Amercable 2/0 AWG Red Jumper Cable Flexible 5000/15000 Volts 90C 37-221-020
- Amercable 3/0 AWG Red Jumper Cable Flexible 5000/15000 Volts 90C 37-221-030
- Amercable 250 MCM Red Jumper Cable Flexible 5000/15000 Volts 90C 37-221-250
- Amercable 350 MCM Red Jumper Cable Flexible 5000/15000 Volts 90C 37-221-350
- Amercable 500 MCM Red Jumper Cable Flexible 5000/15000 Volts 90C 37-221-500
Product Details
Conductors: Flexible-stranded, tinned, annealed coated copper per ASTM B-33
Conductor Shield: Combination semiconducting tape and/or extruded semiconductive thermosetting material. The semiconductive tape prevents any penetration of the extruded conductor shield into the inner layers of the flexible conductor.
Insulation: Heat resisting 90°C Ethylene-Propylene rubber (EPR), meeting ASTM D-2802. It has excellent dielectric properties and is highly resistant to heat, moisture, and ozone.
Jacket: Thermosetting bright red jacket, 90°C rated
Identification: Cable is surface printed showing manufacturer’s name, size, voltage rating, and temperature rating
Application: Portable dual rated 5000/15000 volt jumper cables can be used as temporary jumper leads for portable or mobile substations, or for temporarily by-passing damaged or faulted sections of power cable. The finely stranded conductor provides an exceptionally flexible cable that can be easily trained and connected in confined areas such as transformer vaults and switch gear enclosures.
Features:
• Extremely flexible stranding
• Bright red thermosetting jacket
• The conductor shield is bonded to the insulation – providing easy, clean stripping
• The 90°C insulation has excellent dielectric properties and is highly resistant to heat, moisture and ozone.
Ratings & Approvals:
• ASTM B-33: Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes
• ASTM D2802: Standard Specification for Ozone- Resistant Ethylene-Alkene Polymer Insulation for Wire and Cable
technical specification: | |
size awg/kcmil | 4/0 |
minimum wires per conductor | 532 |
nominal insulation thickness in. | 0.210 |
nominal jacket thickness in. | 0.065 |
nominal outside diameter in. | 1.215 |
approx. weight lbs. per 1,000 ft. | 1181 |
ampacity 90°c at 5kv/15 kv | 400/400 |
amercable part number | 37-221-040 |