General Cable Diesel Locomotive Cable® 14 AWG Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
Select gauge from drop-down menu for prices:
- General Cable Diesel Locomotive Cable® EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 12 AWG Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 10 AWG Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 8 AWG Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 6 AWG Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 4 AWG Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 2 AWG Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 1 AWG Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 1/0 AWG Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 2/0 AWG Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 3/0 AWG Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 4/0 AWG Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 262.6kcmil Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 313.3kcmil Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 373.7kcmil Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 444.4kcmil Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 535.3kcmil Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 646.4kcmil Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 777.7kcmil Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 929.9kcmil Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
- General Cable Diesel Locomotive Cable® 1111.1kcmil Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
Conductor: 14 AWG (2.08 mm) thru 1111.1 kcmil (562 mm) Class I fully annealed flexible stranded tin coated copper per AAR 589
Insulation: Flame-retardant, lead-free cross-linked Ethylene Propylene (EP) with separator tape over the conductor to facilitate stripping
Jacket: Black, flame-retardant, sunlight-, ozoneand oil-resistant, lead-free Cross-linked Chlorinated Polyethylene (XL-CPE)
Options:
• Fully annealed, flexible bare copper stranding per AAR 589
• Other jacket colors available upon request
Applications:
• For use up to 2000 V as power cables in wind turbine generator applications per UL Subject 6140
• Diesel electric locomotives
• Mining and earth-moving equipment
• General purpose use as flexible power leads
• Flexible power leads in cable trays in sizes 1/0 AWG and larger
• Accepted for listing as flame-resistant by MSHA
Features:
• Rated 90°C wet or dry per UL 44/CSA C.22.2-38
• Flexible tinned copper stranding
• Excellent resistance to oils, gear lubricants, ozone, sunlight, heat and flame
• Designed to withstand continuous flexing
Minimum Bend Radius: 8X O.D. for fixed installations or mobile applications
Torsion Requirements: +/-180° twists per meter for 5,000 cycles at -40°C with cable weight compensated to 18 meters
Compliances:
Industry Compliances:
• Type RHH/RHW-2 per UL 44, UL File # E90494
• c(UL)US Type RW90 per CSA C.22.2-38, UL File # E90494
• National Electrical Code (NEC)
• ICEA S-95-658/NEMA WC70
• “For CT Use” on 1/0 AWG and larger in accordance with NEC®
• Accepted for listing as flame resistant by MSHA
• RoHS Compliant
Flame Test Compliances:
• UL 2556 VW-1
• IEEE 1202/CSA FT4 for sizes 1/0 AWG and larger
technical specification : | |
cond. size(awg/kcmil) | 14 |
cond. size(mm²) | 2.08 |
cond.strand
|
19/.0147 |
nominal cond. o.d.(inches) | 0.070 |
nominal cond. o.d.(mm) | 1.8 |
nom. ins.thickness(inches) | 0.045 |
nom. ins.thickness(mm)
|
1.1 |
jacket thickness(inches) | 0.015 |
jacket thickness(mm) | 0.4 |
nominal o.d.(inches) | 0.20 |
nominal o.d.(mm) | 5.1 |
approx.net weight(lbs/1000 ft) | 30 |
approx.net weight(kg/km)
|
45 |
catalog number | 5310.01014 |