General Cable Diesel Locomotive Cable® 444.4kcmil Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C

General Cable Diesel Locomotive Cable® 444.4kcmil Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C

Select gauge from drop-down menu for prices:

General Cable Diesel Locomotive Cable® 444.4kcmil Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C
Diesel Locomotive 444.4kcmil Cable EPR/XL-CPE UL RHH/RHW-2 2KV and RW90 1KV Flexible -40C to 90C

Conductor: 14 AWG (2.08 mm) thru 1111.1 kcmil (562 mm) Class I fully annealed flexible stranded tin coated copper per AAR 589 

Insulation: Flame-retardant, lead-free cross-linked Ethylene Propylene (EP) with separator tape over the conductor to facilitate stripping 

Jacket: Black, flame-retardant, sunlight-, ozoneand oil-resistant, lead-free Cross-linked Chlorinated Polyethylene (XL-CPE)  

Options: 
• Fully annealed, flexible bare copper stranding per AAR 589 
• Other jacket colors available upon request 

Applications: 
• For use up to 2000 V as power cables in wind turbine generator applications per UL Subject 6140 
• Diesel electric locomotives 
• Mining and earth-moving equipment 
• General purpose use as flexible power leads 
• Flexible power leads in cable trays in sizes 1/0 AWG and larger
• Accepted for listing as flame-resistant by MSHA 

Features: 
• Rated 90°C wet or dry per UL 44/CSA C.22.2-38 
• Flexible tinned copper stranding 
• Excellent resistance to oils, gear lubricants, ozone, sunlight, heat and flame 
• Designed to withstand continuous flexing 

Minimum Bend Radius: 8X O.D. for fixed installations or mobile applications 

Torsion Requirements: +/-180° twists per meter for 5,000 cycles at -40°C with cable weight compensated to 18 meters 

Compliances: 
Industry Compliances: 
• Type RHH/RHW-2 per UL 44, UL File # E90494 
• c(UL)US Type RW90 per CSA C.22.2-38, UL File # E90494 
• National Electrical Code (NEC) 
• ICEA S-95-658/NEMA WC70 
• “For CT Use” on 1/0 AWG and larger in accordance with NEC® 
• Accepted for listing as flame resistant by MSHA 
• RoHS Compliant 

Flame Test Compliances: 
• UL 2556 VW-1 
• IEEE 1202/CSA FT4 for sizes 1/0 AWG and larger 

technical specification :
cond. size(awg/kcmil) 444.4
cond. size(mm²) 225
cond.strand
1110/24
nominal cond. o.d.(inches) 0.786
nominal cond. o.d.(mm) 20.0
nom. ins.thickness(inches) 0.090
nom. ins.thickness(mm)
2.3
jacket thickness(inches) 0.065
jacket thickness(mm) 1.7
nominal o.d.(inches) 1.11
nominal o.d.(mm) 28.2
approx.net weight(lbs/1000 ft) 1634
approx.net weight(kg/km)
2432
catalog number 5310.01444

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question