Construction: Annealed stranded circular copper, IEC 60228 class 2

Insulation: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)

Pair/Triple/Quad Twisting: Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples are laid up collectively and screened by aluminum backed polyester tape with tinned copper drain wire. Pairs/triples are identified by numbered tape or by numbers printed directly on the insulated conductors.

Inner Covering: Flame retardant and halogen-free thermoplastic compound

Armour/Screen: Concentric copper conductor.

Outer Sheath: Flame retardant halogen-free thermoplastic compound, SHF1

Marking Text: "meter" "ar" DRAKA NORSK KABEL TFSI(i) 250V 10 PAIR 0,75 mm2 S100 IEC 60092-376 IEC 60332-1

Outer Sheath Colour: Grey or Blue

Core Identification Instrumentation Cables:
• Pair - Black-Light Blue
• Triple - Black-Light Blue-Brown
• Quad - Black-Light Blue-Brown-Grey

Operating Temperature: 90°C

Operating Voltage: 250V

Standards applied:
• IEC 60092-376 - Design
• IEC 60228 class 2 - Conductor
• IEC 60092-351 - Insulation
• IEC 60092-359 - Sheath
• IEC 60332-1 - Flame Retardant

Description:
• TFSI(I) 1 PAIR 0.75mm2 S100
• TFSI(I) 1 PAIR 0.75mm2 S100
• TFSI(I) 2 PAIR 0.75mm2 S100
• TFSI(I) 2 PAIR 0.75mm2 S100
• TFSI(I) 4 PAIR 0.75mm2 S100
• TFSI(I) 4 PAIR 0.75mm2 S100
• TFSI(I) 10 PAIR 0.75mm2 S100
• TFSI(I) 10 PAIR 0.75mm2 S100
• TFSI(I) 16 PAIR 0.75mm2 S100
• TFSI(I) 16 PAIR 0.75mm2 S100
• TFSI(I) 1 TRIP 0.75mm2 S100
• TFSI(I) 1 TRIP 0.75mm2 S100
• TFSI(I) 2 TRIP 0.75mm2 S100
• TFSI(I) 2 TRIP 0.75mm2 S100
• TFSI(I) 4 TRIP 0.75mm2 S100
• TFSI(I) 4 TRIP 0.75mm2 S100
• TFSI(I) 10 TRIP 0.75mm2 S100
• TFSI(I) 10 TRIP 0.75mm2 S100
• TFSI(I) 16 TRIP 0.75mm2 S100
• TFSI(I) 16 TRIP 0.75mm2 S100
• TFSI(I) 1 PAIR 1.5mm2 S100
• TFSI(I) 1 PAIR 1.5mm2 S100
• TFSI(I) 2 PAIR 1.5mm2 S100
• TFSI(I) 2 PAIR 1.5mm2 S100
• TFSI(I) 4 PAIR 1.5mm2 S100
• TFSI(I) 4 PAIR 1.5mm2 S100
• TFSI(I) 10 PAIR 1.5mm2 S100
• TFSI(I) 10 PAIR 1.5mm2 S100
• TFSI(I) 16 PAIR 1.5mm2 S100
• TFSI(I) 16 PAIR 1.5mm2 S100
• TFSI(I) 1 TRIP 1.5mm2 S100
• TFSI(I) 1 TRIP 1.5mm2 S100
• TFSI(I) 2 TRIP 1.5mm2 S100
• TFSI(I) 2 TRIP 1.5mm2 S100
• TFSI(I) 4 TRIP 1.5mm2 S100
• TFSI(I) 4 TRIP 1.5mm2 S100
• TFSI(I) 10 TRIP 1.5mm2 S100
• TFSI(I) 10 TRIP 1.5mm2 S100
• TFSI(I) 16 TRIP 1.5mm2 S100
• TFSI(I) 16 TRIP 1.5mm2 S100

Sheath Colour:
• GREY
• BLUE

Application: Fixed installation indoor, outdoor and above ground for instrumentation and telecommunication systems both in EX- and safe areas.

technical specification:
no of cores in element 2
number of elements 1
cross section core, mm2 0.75
conductor diameter, mm 1.1
insulation thickness, mm 0.5
thickness bedding, mm 1.1
diameter bedding, mm 6.5 ± 0.5
wire diameter concentric conductor, mm 0.61
thickness outer sheath, mm 1
diameter outer sheath, mm 10 ± 0.8
weight of cable approx. (kg/km) 155
copper content approx. (kg/km) 49
draka cable part number 856000