Draka Cable 30 Elements 1.5 Cross-section TFSI 0,6/1kV HFXLPE/LSTPE/CWS/PO Flame Retardant Cable for Power Control and Lighting 850516

Draka Cable 30 Elements 1.5 Cross-section TFSI 0,6/1kV HFXLPE/LSTPE/CWS/PO Flame Retardant Cable for Power Control and Lighting 850516

Select gauge from drop-down menu for prices:

Draka Cable 30 Elements 1.5 Cross-section TFSI 0,6/1kV HFXLPE/LSTPE/CWS/PO Flame Retardant Cable for Power Control and Lighting 850516
Draka Cable 30 Elements 1.5 Cross-section TFSI 0,6/1kV HFXLPE/LSTPE/CWS/PO Flame Retardant Cable for Power Control and Lighting 850516

Construction: Annealed stranded copper, IEC 60228 class 2, stranded circular copper SCC (single core cables 1,5 ... 300 mm2, multicore cables 1,5 ... 35 mm2), sector shaped copper SSC (3 and 4 core cables above 35 mm2)

Insulation: Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)

Lay up / Shielding: Cores laid up in concentric layers

Inner Covering: Flame retardant and halogen-free thermoplastic compound

Armour/Screen: Concentric copper conductor. Sized to be earth conductor.

Outer Sheath: Flame retardant halogen-free thermoplastic compound, SHF1

Marking Text: "meter" "year" DRAKA 01 TFSI 0,6/1kV 3 x 25FR/16 mm2 P105 IEC 60332-1

Manufacturing Unit: DRAKA 01 = Draka Norsk Kabel

Outer Sheath Colour: Black

Core Identification Power Cables:
• Single core - Black
• Two cores - Blue-Brown
• Three cores - Brown-Black-Grey
• Four cores - Blue-Brown-Black-Grey
• Five cores - Blue-Brown-Black-Grey-Black
• Seven cores and above - White with black numbers
• Two cores + earth (3G) - Yellow/green-Blue-Brown
• Three cores + earth (4G) - Yellow/green-Brown-Black-Grey
• Four cores + earth (5G) - Yellow/green-Blue-Brown-Black-Grey
• G / X in cable description - One of the cores are yellow/green - X = no yellow/green core
• Core identification - to HD308S2 - and IEC 60446:2007-05

Operating Temperature: 90°C

Operating Voltage: 0,6/1kV

Standards applied:
• IEC 60502-1 - Design
• IEC 60228 class 2 - Conductor
• IEC 60092-351 - Insulation
• IEC 60092-359 - Sheath
• IEC 60332-1 - Flame Retardant

Description:
• TFSI 0,6/1kV 2X 1.5/1.5 P105
• TFSI 0,6/1kV 3X 1.5/1.5 P105
• TFSI 0,6/1kV 7X 1.5/1.5 P105
• TFSI 0,6/1kV 12X 1.5 FR/1.5MM2 P105
• TFSI 0,6/1kV 19X 1.5/1.5 P105
• TFSI 0,6/1kV 30X 1.5/1.5 P105
• TFSI 0,6/1kV 48X 1.5/1.5 P105
• TFSI 0,6/1kV 2X 2.5 FR/2.5 P105
• TFSI 0,6/1kV 3X 2.5 FR/2.5 P105
• TFSI 0,6/1kV 4X 2.5 FR/2.5 P105
• TFSI 0,6/1kV 7X 2.5 FR/2.5 P105
• TFSI 0,6/1kV 12X 2.5 FR/2.5MM2 P105
• TFSI 0,6/1kV 19X 2.5 FR/2.5 P105
• TFSI 0,6/1kV 2X 4 FR/4MM2 P105
• TFSI 0,6/1kV 3X 4 FR/4MM2 P105
• TFSI 0,6/1kV 4X 4 FR/4MM2 P105
• TFSI 0,6/1kV 2X 6 FR/6MM2 P105
• TFSI 0,6/1kV 3X 6 FR/6MM2 P105
• TFSI 0,6/1kV 4X 6 FR/6MM2 P105
• TFSI 0,6/1kV 2X 10 FR/10MM2 P105
• TFSI 0,6/1kV 3X 10 FR/10MM2 P105
• TFSI 0,6/1kV 4X 10 FR/10MM2 P105
• TFSI 0,6/1kV 2X 16 FR/16MM2 P105
• TFSI 0,6/1kV 3X 16 FR/16MM2 P105
• TFSI 0,6/1kV 4X 16 FR/16MM2 P105
• TFSI 0,6/1kV 2X 25 FR/16 P105
• TFSI 0,6/1kV 3X 25 FR/16MM2 P105
• TFSI 0,6/1kV 4X 25 FR/16 P105
• TFSI 0,6/1kV 3X 35 FR/16MM2 P105
• TFSI 0,6/1kV 4X 35 FR/16 P105
• TFSI 0,6/1kV 3X 50 FV/25MM2 P105
• TFSI 0,6/1kV 4X 50 FV/25MM2 P105
• TFSI 0,6/1kV 3X 70 FV/35MM2 P105
• TFSI 0,6/1kV 4X 70 FV/35MM2 P105
• TFSI 0,6/1kV 3X 95 FV/50MM2 P105
• TFSI 0,6/1kV 4X 95 FV/50 P105
• TFSI 0,6/1kV 3X 120 FV/70 P105
• TFSI 0,6/1kV 4X 120 FV/70 P105
• TFSI 0,6/1kV 3X 150 FV/70 P105
• TFSI 0,6/1kV 4X 150 FV/70 P105
• TFSI 0,6/1kV 3X 185 FV/95 P105
• TFSI 0,6/1kV 4X 185 FV/95 P105
• TFSI 0,6/1kV 3X 240 FV/120 P105
• TFSI 0,6/1kV 4X 240 FV/120 P105
• TFSI 0,6/1kV 1X 240 FV/50 P105
• TFSI 0,6/1kV 1X 300 FV/50 P105
• TFSI 0,6/1kV 1X 400 FV/70 P105
• TFSI 0,6/1kV 1X 500 FV/95 P105
• TFSI 0,6/1kV 1X 630 FV/120MM2 P105

Sheath Colour: BLACK

Application: Fixed installation indoor, outdoor and above ground for power, control and lighting systems both in EX- and safe areas.

technical specification:
number of elements 30
cross section core, mm2 1.5
cross section screen, mm2 1.5
conductor diameter, mm 1.6
insulation thickness, mm 0.7
thickness inner covering, mm 1.2
diameter inner covering, mm 21.5 ± 1
wire diameter concentric conductor, mm 0.6
thickness outer sheath, mm 1.8
diameter outer sheath, mm 26.5 ± 1
weight of cable approx. (kg/km) 850
copper content approx. (kg/km) 477
draka cable part number 850516