General Cable Instrumentation Cable 18/25 Gauge 600V VW-1 ULTROL® 60+

General Cable Instrumentation Cable 18/25 Gauge 600V VW-1 ULTROL® 60+

Select gauge from drop-down menu for prices:

General Cable Instrumentation Cable 18/25 Gauge 600V VW-1 ULTROL® 60+

Conductor: 18 AWG and 16 AWG tinned annealed copper per ASTM B33; Class B stranding per ASTM B8

Insulation:
• Flame-retardant, heat-, moisture- and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyethylene (FR-XLPE)
• Color code: Per ICEA Method 1, Table E-1

Jacket: Flame-retardant, moisture-, oil-, sunlight-, and radiation-resistant, thermoset ULTROL® 60+ Cross-linked Polyolefin (XLPO) — Black

Print: GENERAL CABLE (WC) ULTROL® 60+ XX/C XXAWG COPPER FR-XLPE XLPO 600 V 90°C SUN RES OIL RES I & II DIR BUR NUCLEAR DAY MONTH YEAR TRACEABILITY NUMBER SEQUENTIAL FOOTAGE MARK

Options:
• Conductor stranding
• ISO Metric conductors

Applications:
• ULTROL® 60+ instrumentation cable is a 600 V multi-conductor, thermoset, Class 1E rated construction specifically designed for applications in nuclear generating stations and where flame retardancy is critical
• For use in Class 1E monitoring data recording and transmitting information on low energy circuits where shielding from external electrostatic interference is not required
• Can be installed in trays, conduit, ducts, or in direct burial applications

Features:
• Rated at 90°C wet or dry
• Fully traceable
• Qualified for 60-year service life
• Gamma and beta radiation resistant (up to 350 megarads)
• Submergence operability
• Long-term thermal endurance and superior electricals
• Excellent mechanical cut-through properties
• Long-term moisture and radiation stability
• Free stripping for ease of termination
• Meets cold bend test at -40°C

Industry Compliances:
• Class 1E Qualified in accordance with IEEE 323-1974/2003 and IEEE 383-1974/2003
• ICEA S-73-532

Flame Test Compliances:
• IEEE 383:1974
• IEEE 383:2003
• ICEA T-29-520
• IEEE 1202/FT4-1991, Aged & Unaged
• VW-1

Other:
• Quality assurance program in accordance with NRC 10CFR50 Appendix B
• ANSI N45.2
• ASME NQA-1
• NIAC
• NUPIC

Packaging: Material to be shipped on non-returnable wooden reels

technical specifications:
cond. size (awg) 18
no. of cond. 25
cond. strand 7/.0152
minimum avg. insulation thickness(inches) 0.025
minimum avg. insulation thickness(mm) 0.64
minimum avg. jacket thickness(inches) 0.060
minimum avg. jacket thickness(mm) 1.52
nominal cable o.d.(inches) 0.730
nominal cable o.d.(mm) 18.54
copper weight(lbs/ 1000 ft) 127
copper weight(kg/km) 189
net weight(lbs/ 1000 ft) 327
net weight(kg/km) 486
catalog number 20060.18.25