Belden 14 AWG Pairs Overall Beldfoil Shielding UL Instrumentation 600V Tinned Copper Tray Cable

Belden 14 AWG Pairs Overall Beldfoil Shielding UL Instrumentation 600V Tinned Copper Tray Cable

Select gauge from drop-down menu for prices:

Belden 14 AWG Pairs Overall Beldfoil Shielding UL Instrumentation 600V Tinned Copper Tray Cable

Regular price $9.96 $7.34 Sale /per Foot

Belden 14 AWG Pairs Overall Beldfoil Shielding UL Instrumentation 600V Tinned Copper Tray Cable

Reliability – even in the harshest of environments – is the hallmark of Belden instrumentation cables.

No matter what gauge size, conductor count, insulation, jacket, armor or rating, Belden meets your need for reliability, performance, security and long life — guaranteed.

Benefits:
• Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit
• Superior electrical performance and longer runs in dozens of different environments
• Assured, flexible installation connections with all the necessary ratings

Features:
• Jacket options for excellent resistance to oil, outdoor sunlight/UV, flame and extreme temperatures
• Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexiblity
• Conductor options to provide increased flexibilty, greater flex life and corrosion resistance

Insulation:
• Material: PVC/Nylon - Polyvinyl Chloride/Nylon

Outer Shield Drain Wire AWG:
• AWG: 14
• Stranding: 19x26
• Material: TC - Tinned Copper

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 8.771
• Nom. Wall Thickness (mm): 1.176
• Outer Jacket Ripcord: Yes

Mechanical Charactertistics (Overall):
• Wet Temperature Range: -30°C To +75°C
• Dry Temperature Range: -30°C To +90°C
• Max. Recommended Pulling Tension: 160 lbs.
• Min. Bend Radius/Minor Axis: 3.750 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: NPLF, TC
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: ICEA S-73-532, S-61-402

Electrical Characteristics (Overall):
• Nom. Inductance (?H/ft): 0.18
• Nom. Capacitance Conductor to Conductor (pF/ft) : 50
• Nom. Capacitance Cond. to Other Conductor and Shield (pF/ft) : 102
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 2.6
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 2.4
• Max. Operating Voltage - UL: 600 V RMS (NEC Type TC)
• Max. Operating Voltage - UL: 150 V RMS (NPLF)
• Max. Recommended Current: 25 Amps/conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 UL Loading
• C(UL) Flame Test: FT4
• IEEE Flame Test: 1202

Suitability:
• Suitability - Burial: Yes
• Sunlight Resistance: Yes

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # pairs overall cable-
nominal dia. (mm)
belden cable
part number
Action
14 1 9.093 9343 Request A Quote

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question