Select gauge from drop-down menu for prices:
- Belden 23505 18 AWG 1 Triad 300V ACIC Armored Aluminum Cable
- Belden 23516 18 AWG 2 Triads 300V ACIC Armored Aluminum Cable
- Belden 23515 18 AWG 4 Triads 300V ACIC Armored Aluminum Cable
- Belden 23508 18 AWG 6 Triads 300V ACIC Armored Aluminum Cable
- Belden 23523 18 AWG 8 Triads 300V ACIC Armored Aluminum Cable
- Belden 23512 18 AWG 12 Triads 300V ACIC Armored Aluminum Cable
- Belden 23537 18 AWG 16 Triads 300V ACIC Armored Aluminum Cable
- Belden 23536 18 AWG 24 Triads 300V ACIC Armored Aluminum Cable
- Belden 26522 18 AWG 1 Triad 300V ACIC Armored Steel Cable
- Belden 26523 18 AWG 2 Triads 300V ACIC Armored Steel Cable
- Belden 26524 18 AWG 4 Triads 300V ACIC Armored Steel Cable
- Belden 26525 18 AWG 6 Triads 300V ACIC Armored Steel Cable
- Belden 26526 18 AWG 8 Triads 300V ACIC Armored Steel Cable
- Belden 26527 18 AWG 12 Triads 300V ACIC Armored Steel Cable
- Belden 26528 18 AWG 16 Triads 300V ACIC Armored Steel Cable
- Belden 26529 18 AWG 24 Triads 300V ACIC Armored Steel Cable
Product Details
Suitable for use in 300V, 600V or some 1000V environments, Belden offers a complete line of unarmored CSA-rated control, instrumentation and power cables.
Combined with a wide range of conductor, insulation and jacket options, Belden has the right cable solution to fit your needs.
Benefits:
• Eliminates the need for costly conduit or burial piping
• Provides superior mechanical protection for use in underground or hazardous environments
• Resists sunlight, chemicals and oil for long-life performance
Features:
• Designed specifically to meet CSA22.2 Type CIC standard
• Wide range of conductor and pair counts
• Armored options available
Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.635
Inner Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Dia. (mm): 8.382
Outer Shield Drain Wire AWG:
• AWG: 20
• Stranding: 7x28
• Material: TC - Tinned Copper
Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Outer Jacket Ripcord: Yes
• Outer Jacket over Armor (y/n): Y
Armor:
• Armor Type: Interlocked
• Armor Material: Aluminum
Mechanical Charactertistics (Overall):
• Installation Temperature Range: -25°C To +105°C
• Wet Temperature Range: -40°C To +75°C
• Dry Temperature Range: -40°C To +105°C
• Non-UL Temperature Rating: 105°C
• Bulk Cable Weight: 260.435 Kg/Km
• Max. Recommended Pulling Tension: 355.856 N
• Min. Bend Radius/Minor Axis: 185.420 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• CSA Specification: C22.2#239, Type ACIC, C22.2#174, HLBCD, C22.2#0.3, Clause 4.31 Low Acid Test
• EU Directive 2011/65/EU (ROHS II): Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 22.3108
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 32.81
• Max. Operating Voltage - Non-UL: 300 (CSA ACIC)
Flame Test:
• C(UL) Flame Test: FT4
Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
awg | # triads | belden cable part number |
Action | ||
al. | steel | aluminum | steel | ||
18 | 18 | 1 | 23505 | 26522 | Request A Quote |
18 | 18 | 2 | 23516 | 26523 | Request A Quote |
18 | 18 | 4 | 23515 | 26524 | Request A Quote |
18 | 18 | 6 | 23508 | 26525 | Request A Quote |
18 | 18 | 8 | 23523 | 26526 | Request A Quote |
18 | 18 | 12 | 23512 | 26527 | Request A Quote |
18 | 18 | 16 | 23537 | 26528 | Request A Quote |
18 | 18 | 24 | 23536 | 26529 | Request A Quote |