Belden Cable Marine Classic Premium Ground Symmetrical Design Thermoset LSZH Jacket VFD Cable
Select gauge from drop-down menu for prices:
- Belden 29528X Cable 1 AWG 3 Conductors Marine Classic Premium Ground Symmetrical Design Thermoset LSZH Jacket VFD Cable
- Belden 29529X Cable 1/0 AWG 3 Conductors Marine Classic Premium Ground Symmetrical Design Thermoset LSZH Jacket VFD Cable
- Belden 29530X Cable 2/0 AWG 3 Conductors Marine Classic Premium Ground Symmetrical Design Thermoset LSZH Jacket VFD Cable
- Belden 29531X Cable 3/0 AWG 3 Conductors Marine Classic Premium Ground Symmetrical Design Thermoset LSZH Jacket VFD Cable
- Belden 29532X Cable 4/0 AWG 3 Conductors Marine Classic Premium Ground Symmetrical Design Thermoset LSZH Jacket VFD Cable
Product Details
Classic Symmetrical Designs Features:
• Available with high-strand conductors in large AWG sizes
• Design features a copper tape shield with segmented ground
• Smaller OD than the Classic Designs with Foil/Braid
• Industrial-grade PVC jackets provide sunlight- and oil-resistance; Haloarrest jackets are halogen-free and provide sunlight-resistance in LSZH versions
• Optimum shielding design (300%/100% copper at ground potential)
• Heavy industrial-grade XLPE insulation
• Finely stranded tinned or bare copper conductors
Technical Data:
• Type: Premium 100% ground three conductor
• Shielding: Dual Copper Tape
• Grounding: Bare 3x Segmented
• Insulation: XLPE (RHHW-2 Thickness)
• Conductor: Stranded Tinned Copper
• Rating: 1000V UL Flexible Motor Supply
• 600V UL 1277 Type TC-ER
• CSA FT4
• IEEE 1202
• UL Oil Res 2 & IEC 60811-2-1 Hydrocarbon resistant
• UL 1685 Vertical Tray Flame Test
• XHHW-2, rated circuit conductors
• -40° C cold bend, IEC 60332-3-22 Cat A (flame test)
• 90° C Wet/Dry
• Suitable for Class I, II & III, Division 2 hazardous locations
• IEC 60754-1,-2 (acid gas emissions)
• MSHA (pending approval)
• RoHS compliant
• CE approved
• Marine approvals: ABS, DNV, UL 1309 Type, IEEE 45, IEEE1580 Type P
Benefits:
• Superior protection against electrical noise
• Increased stability in electrical performance
• Improved system uptime in harsh environments
awg |
cond. stranding |
minimum bend radius |
belden cable part number |
Action | |
inch | mm | ||||
1 | 7 x 19 x 22 | 12.0 | 304.8 | 29528X | Request A Quote |
1/0 | 7 x 19 x 21 | 12.9 | 327.7 | 29529X | Request A Quote |
2/0 | 7 x 19 x 20 | 14.0 | 355.6 | 29530X | Request A Quote |
3/0 | 7 x 19 x 19 | 15.2 | 386.1 | 29531X | Request A Quote |