2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation
Select gauge from drop-down menu for prices:
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 00603
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 00403
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 00203
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 00103
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 10103
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 20103
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 40103
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 25003
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 35003
- 2.4KV UL Type MV 105, MC-HL, CT, 105, EPR Insulation - HW309 50003
Specifications:
- Impervious Continuously Welded Armor - Power Cable
- 2.4KV UL Type MV 105, MC-HL, CT Use, 105°C
- Non-Shielded, EPR Insulation
- 133% Insulation Level
- Aluminum Armor
- Copper Conductors
Application:
For use in harsh environments where maximum conductor protection is required. Used for primary power and feeder circuits in a broad range of commercial and industrial power distribution systems. Approved for use in wet or dry locations at 105°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 2400 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. National Electric Code approved for use at 105°C for continuous operation, 140°C for emergency overload conditions, and 250°C for short circuit conditions. Impervious continuously welded and corrugated aluminum armor cable is recommended as an economical alternative to wire in conduit systems.
Conductors:
Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact), with a semi-conducting conductor shield.
Insulation:
Ethylene propylene rubber (EPR) per ICEA S-96-659.
Grounding Conductor: Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL 1072.
Armor:
Impervious continuously welded and corrugated aluminum.
Jacket:
Yellow flame-retardant and sunlight-resistant PVC.
Flame Tests:
ICEA 70,000 BTU/hr and 210,000 BTU/hr flame test
Color Code:
ICEA Method 4
Additional Standards:
- NEMA WC 71
- UL 1309 listed as Marine Shipboard Cable
Connectors:
- Explosion Proof, Class I Division 1: 424MA series - exterior components - aluminum, interior components - nickel-plated brass
- Rain Tight: 416MC series - all nickel-plated brass
- See 424MA series in Section J.
Power Size AWG/kcmil |
No. of Strands | Net Weight Lbs./Mft |
Catalog Number | Action |
6 | 7 | 730 | HW309 00603 / HW30900603 |
Request A Quote |
4 | 7 | 920 | HW309 00403 / HW30900403 |
Request A Quote |
2 | 7 | 1215 | HW309 00203 / HW30900203 |
Request A Quote |
1 | 19 | 1525 | HW309 00103 / HW30900103 |
Request A Quote |
1/0 | 19 | 1810 | HW309 10103 / HW30910103 |
Request A Quote |
2/0 | 19 | 2130 | HW309 20103 / HW30920103 |
Request A Quote |
4/0 | 19 | 3040 | HW309 40103 / HW30940103 |
Request A Quote |
250 | 19 | 3475 | HW309 25003 / HW30925003 |
Request A Quote |
350 | 37 | 4695 | HW309 35003 / HW30935003 |
Request A Quote |
500 | 37 | 6315 | HW309 50003 / HW30950003 |
Request A Quote |