Prysmian and Draka Cable 20 and 18 AWG Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable
Select gauge from drop-down menu for prices:
- Prysmian and Draka Cable 20 AWG 1 Pair Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26338
- Prysmian and Draka Cable 20 AWG 2 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26339
- Prysmian and Draka Cable 20 AWG 3 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26340
- Prysmian and Draka Cable 20 AWG 4 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26341
- Prysmian and Draka Cable 20 AWG 5 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26342
- Prysmian and Draka Cable 20 AWG 6 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26343
- Prysmian and Draka Cable 20 AWG 7 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26344
- Prysmian and Draka Cable 20 AWG 8 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26345
- Prysmian and Draka Cable 20 AWG 10 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26346
- Prysmian and Draka Cable 20 AWG 12 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26347
- Prysmian and Draka Cable 20 AWG 16 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26348
- Prysmian and Draka Cable 20 AWG 20 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26349
- Prysmian and Draka Cable 20 AWG 24 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26350
- Prysmian and Draka Cable 18 AWG 1 Pair Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable
- Prysmian and Draka Cable 18 AWG 2 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26352
- Prysmian and Draka Cable 18 AWG 3 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26353
- Prysmian and Draka Cable 18 AWG 4 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26354
- Prysmian and Draka Cable 18 AWG 5 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26355
- Prysmian and Draka Cable 18 AWG 6 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26356
- Prysmian and Draka Cable 18 AWG 7 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26357
- Prysmian and Draka Cable 18 AWG 8 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26358
- Prysmian and Draka Cable 18 AWG 10 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26359
- Prysmian and Draka Cable 18 AWG 12 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26360
- Prysmian and Draka Cable 18 AWG 16 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26361
- Prysmian and Draka Cable 18 AWG 20 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26362
- Prysmian and Draka Cable 18 AWG 24 Pairs Bostrig Type P Individual and Overall Shielded Multipair Unarmored 600V Signal Cable T26363
Product Details
Conductors: Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used over the conductor.
Insulation: Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580.
Shield: An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair and the cabled core. The single pair construction has only the overall shield and drain wire.
Jacket: Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) in accordance with the requirements of IEEE- 1580-2010. Thickness as shown in tables on opposite page. Arctic Neoprene (Type N) also available as an option.
Applications:
• Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities.
• Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored and sheathed).
• The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3).
• This product may be manufactured in an unarmored or armored and sheathed version.
Features/Ratings:
• Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
• High strand count conductors provide superior flexibility
• Higher allowable conductor operating temperature results in increased ampacity
• Cold bend/ cold impact of -40°/ -35°C in accordance with CSA 22.2 No. 0.3
• Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A
• Meets IEEE standards for 600V and performance requirements of IEC standards for 0.6/1 kV
• Unarmored cables suitable for Class 1, Division 2 and Zone 2 hazardous locations offshore
• Meets the requirements of UL 1277 and UL 1569 for Type TC-ER exposed runs
Approvals:
• IEEE 1580 and IEEE 45- Marine Shipboard Cable
• UL 1309- Marine Shipboard Cable Type X110
• CSA 22.2 No. 245- Marine Shipboard Cable Type X110
• CSA 22.2 No. 239- Type CIC
• CSA 22.2 No. 230 as Type TC (#18 AWG)
• Det Norske Veritas (DNV)
• American Bureau of Shipping (ABS)
• Transport Canada Approved AMS400-20-2
• Transport Canada 8700-20-2
• Lloyd’s Register of Shipping (LRS)
• United States Coast Guard-46CFR
conductor size (awg) |
number of pairs |
type designation |
Prysmian and draka Cable part number |
Action |
20 awg • 0.61 mm² | ||||
20 | 1 | tp(0s)20pn-1 | T26338 | Request A Quote |
20 | 2 | tp(i/s-0s)20pn-2 | T26339 | Request A Quote |
20 | 3 | tp(i/s-0s)20pn-3 | T26340 | Request A Quote |
20 | 4 | tp(i/s-0s)20pn-4 | T26341 | Request A Quote |
20 | 5 | tp(i/s-0s)20pn-5 | T26342 | Request A Quote |
20 | 6 | tp(i/s-0s)20pn-6 | T26343 | Request A Quote |
20 | 7 | tp(i/s-0s)20pn-7 | T26344 | Request A Quote |
20 | 8 | tp(i/s-0s)20pn-8 | T26345 | Request A Quote |
20 | 10 | tp(i/s-0s)20pn-10 | T26346 | Request A Quote |
20 | 12 | tp(i/s-0s)20pn-12 | T26347 | Request A Quote |
20 | 16 | tp(i/s-0s)20pn-16 | T26348 | Request A Quote |
20 | 20 | tp(i/s-0s)20pn-20 | T26349 | Request A Quote |
20 | 24 | tp(i/s-0s)20pn-24 | T26350 | Request A Quote |
18 awg • 0.96 mm² | ||||
18 | 1 | tp(0s)18pn-1 | - | Request A Quote |
18 | 2 | tp(i/s-0s)180pn-2 | T26352 | Request A Quote |
18 | 3 | tp(i/s-0s)18pn-3 | T26353 | Request A Quote |
18 | 4 | tp(i/s-0s)18pn-4 | T26354 | Request A Quote |
18 | 5 | tp(i/s-0s)18pn-5 | T26355 | Request A Quote |
18 | 6 | tp(i/s-0s)18pn-6 | T26356 | Request A Quote |
18 | 7 | tp(i/s-0s)18pn-7 | T26357 | Request A Quote |
18 | 8 | tp(i/s-0s)18pn-8 | T26358 | Request A Quote |
18 | 10 | tp(i/s-0s)18pn-10 | T26359 | Request A Quote |
18 | 12 | tp(i/s-0s)18pn-12 | T26360 | Request A Quote |
18 | 16 | tp(i/s-0s)18pn-16 | T26361 | Request A Quote |
18 | 20 | tp(i/s-0s)18pn-20 | T26362 | Request A Quote |
18 | 24 | tp(i/s-0s)18pn-24 | T26363 | Request A Quote |